RS-232C Specifications and Command Settings

PC control

A computer can be used to control the projector by connecting an RS-232C serial control cable (cross type, sold separately) to the projector. (See page 20 for connection.)

Communication conditions

Set the serial port settings of the computer to match that of the table.

Signal format: Conforms to RS-232C standard.

Baud rate: 9,600 bps

Data length: 8 bits

Parity bit: None

Stop bit: 1 bit

Flow control: None

Basic format

Commands from the computer are sent in the following order: command, parameter, and return code. After the projector processes the command from the computer, it sends a response code to the computer.

Command format

 

C1 C2

C3

C4

P1

P2

P3

P4

 

 

 

 

 

Return code (0DH)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Command 4-digit

Parameter 4-digit

 

 

 

 

Response code format

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Normal response

 

Problem response (communication error or incorrect command)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

O

K

 

 

Return code (0DH)

 

 

 

E

R

R

 

Return code (0DH)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Info

When more than one code is being sent, send each command only after the response code for the previous command from the projector is verified.

Commands

Example: When turning on the projector, make the following setting.

 

 

 

 

Computer

 

 

 

 

 

Projector

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P

O

W

R

_

_

 

 

_

1

 

O

K

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CONTROL CONTENTS

 

COMMAND PARAMETER

 

RETURN

 

 

 

 

 

Power Off (Standby)

 

P O W R _ _ _ 0

OK or ERR

 

 

 

 

 

Power On

 

P O W R _ _ _ 1

OK or ERR

 

 

 

 

 

INPUT1

 

I

R G B _ _ _ 1

OK or ERR

 

 

 

 

KEY

INPUT2

 

I

V E D _ _ _ 1

OK or ERR

 

 

 

 

INPUT3

 

I

V E D _ _ _ 2

OK or ERR

 

 

 

 

CONTROL

 

 

 

 

 

Lamp Usage Time (hour)

 

T L T T _ _ _ 1

0~9999

 

 

 

 

 

 

 

 

 

 

 

 

 

Remaining Lamp Life (Percentage)

 

T L T L _ _ _ 1

0~100

 

 

 

 

 

REMOTE&

Lamp Status

 

T L P S _ _ _ 1

0:Off, 1:On, 2:Retry, 3:Waiting, 4:Lamp Error

 

 

 

Unit Status

 

T A B N _ _ _ 1

4:Filter Cover Err, 8:Lamp 100 hours,

 

 

 

 

BUTTONS

 

0:Normal, 1:Temp High, 2:Fan Err,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16:Lamp Burnt-out, 32:Lamp Not Lit,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

64:Temp Abnormally High

 

 

 

 

 

Model Name Check

 

T N A M _ _ _ 1

PROJECTOR NAME

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AV Mute Off

 

I M B K _ _ _ 0

OK or ERR

 

 

 

 

 

AV Mute On

 

I M B K _ _ _ 1

OK or ERR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Auto Sync Start

 

A D J S _ _ _ 1

OK or ERR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note

If an underbar (_) appears in the parameter column, enter a space. If an asterisk (*) appears, enter a value in the range indicated in brackets under CONTROL CONTENTS.

61

Appendix

A10X_A10S#E_Print#p51_62.p65

61

03.2.4, 2:07 PM

Page 65
Image 65
Sharp PG-A10S RS-232C Specifications and Command Settings, PC control, Communication conditions, Basic format, Commands