Maintenance Indicators
■The warning lights on the projector indicate problems inside the projector.
■If a problem occurs, either the temperature warning indicator or the lamp replacement indicator will illuminate red, and the power will turn off. After the power has been turned off, follow the proce- dures given below.
Power indicator
Lamp replacement indicator About the lamp replacement indicator
Temperature warning indicator
About the temperature warning indicator
If the temperature inside the pro- jector increases, due to blockage of the air vents, or the setting lo-
cation, “” will illuminate in
the lower left corner of the picture. If the temperature keeps on rising, the lamp will turn off and the tem- perature warning indicator will blink, the cooling fan will run for a further 90 seconds, and then the power will be shut off. After
“” appears, be sure to per- form the following measures.
■The lamp life becomes 0%, when used for approximately 4,500 hours with “Eco Mode” or when used for approximately 3,000 hours with “Standard Mode” (see page 45).
■When the remaining lamp life becomes
5% or less, “” (yellow) will be displayed on the screen. When the percentage be-
comes 0%, “” will change to “” (red), the lamp will automatically turn off and then the projector as well. At this time, the lamp replacement indicator will illu- minate in red.
■If you try to turn on the projector a fourth time without replacing the lamp, the pro- jector will not turn on.
Maintenance indicator | Condition | Problem | Possible Solution | ||||
|
|
| |||||
| Normal | Abnormal | |||||
|
|
|
|
| |||
|
|
|
|
|
|
| |
|
|
|
| • Blocked air intake | • Relocate the projector to an area | ||
|
|
|
| with proper ventilation. | |||
Temperature |
|
| The internal |
| |||
|
|
|
|
| |||
warning | Off | Red on/ | temperature is | • Cooling fan break- | • Take the projector to your nearest | ||
down | Sharp Authorized Projector Dealer | ||||||
indicator | Power off | abnormally high. | |||||
| • Internal circuit failure | or Service Center (see page 65) | |||||
|
|
|
| ||||
|
|
|
| • Clogged air intake | for repair. | ||
|
|
|
|
|
|
| |
| Green on | Red on | Time to change | • Remaining lamp life | • Carefully replace the lamp. (See | ||
| the lamp | becomes 5% or less. | page 58) | ||||
Lamp | Green |
| • Take the projector to your nearest | ||||
blinks |
|
|
| Sharp Authorized Projector Dealer | |||
replacement |
|
|
| ||||
when the |
|
|
| or Service Center (see page 65) | |||
indicator | Red on/ | The lamp does | • | ||||
lamp is | for repair. | ||||||
| Power off | not illuminate. | • Lamp circuit failure | ||||
| active. | • Please exercise care when | |||||
|
|
|
| ||||
|
|
|
|
| replacing the lamp. | ||
|
|
|
|
|
|
| |
|
|
|
|
| • Securely install the cover. | ||
|
|
| The power |
| • If the power indicator blinks even | ||
Power | Green on/ | Red blinks | indicator blinks | • The filter/lamp unit | when the filter/lamp unit cover is | ||
indicator | Red on | in red when the | cover is open. | securely installed, contact your | |||
| |||||||
|
|
| projector is on. |
| nearest Sharp Authorized Projec- | ||
|
|
|
|
| tor Dealer or Service Center for | ||
|
|
|
|
| advice. | ||
|
|
|
|
|
|
|
55