Regarding the Lamp

Removing and Installing the Lamp Unit

Info

Be sure to remove the lamp unit using the handle. Be sure not to touch the glass sur- face of the lamp unit or the inside of the projector.

To avoid injury to yourself and damage to the lamp, be sure to carefully follow the steps below.

Do not loosen other screws except for the filter/lamp unit cover and lamp unit.

Please refer to the installation manual in- cluded with the lamp unit.

1 Press on the projector to turn off the power.

Wait until the cooling fan stops.

Warning!

Do not remove the lamp unit from the projector right after use. The lamp will be very hot and may cause burn or injury.

2 Disconnect the power cord.

Unplug the power cord from the AC socket.

Leave the lamp until it has fully cooled down (about 1 hour).

3 Change the air filter.

Change the air filter whenever you in- stall the lamp unit (see pages 53 and 54).

4 Remove the filter/lamp unit cover.

Turn the projector over. Loosen the user service screw (1) that secures the fil-

ter/lamp unit cover. Pressing the tab (2), remove the filter/lamp unit cover (3).

58

Lamp

unit

BQC-PGA10X//1

 

Power OFF button

AC socket

1

3

User

service

screw

2 Tab

A10X_A10S#E_Print#p51_62.p65

58

03.2.4, 2:07 PM

Page 62
Image 62