| INSTALLATION |
|
|
| |||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
TECHNICAL | |||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
| RATED INPUT - SINGLE PHASE ONLY |
|
|
| |||||||||||||
|
|
| Duty |
|
|
|
|
|
| Voltage + 10% |
|
|
| Max. Amps With Power Factor Capacitor |
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| 40% |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
| AC/DC Stick / Balance TIG |
|
|
|
|
|
|
|
|
|
|
|
|
| 119/69/63 |
|
|
| Unbalance (70% Penetration#) AC TIG |
|
|
|
|
|
|
|
|
|
|
|
|
| 118/68/62 |
|
| ||
|
| 60% |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
| AC/DC Stick / Balance TIG |
|
|
|
|
|
|
|
|
|
|
|
|
| 110/64/59 |
|
|
| Unbalance (70% Penetration#) AC TIG |
|
|
|
|
|
|
|
|
|
|
|
| 97/56/52 |
|
| |||
| 100% |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
| AC/DC Stick / Balance TIG |
|
|
|
|
|
|
|
|
|
|
|
|
| 88/51/47 |
|
|
| Unbalance (70% Penetration#) AC TIG |
|
|
|
|
|
|
|
|
|
|
|
|
| 73/42/39 |
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
| Idle Amps |
|
|
|
|
|
|
|
|
|
|
|
|
| 48/28/25 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
| Rated Power Factor (Stick) |
|
|
|
|
|
|
|
|
|
|
|
|
| .67 min. |
| |
|
|
| Idle Power |
|
|
|
|
|
|
|
|
|
|
|
|
| .8KW |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| RATED OUTPUT - IEC |
|
|
| |||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
| Duty |
|
|
|
|
|
| |||||||||||
|
|
|
|
|
|
|
| Volts at Rated Amperes |
|
| Amps | ||||||||
| 40% |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
| AC/DC Stick / Balance TIG |
|
| 35.0 |
|
|
|
|
|
| 375 |
|
| |||||
| Unbalance (70% Penetration#) AC TIG |
|
| 24.0 |
|
|
|
|
|
| 350 |
|
| ||||||
| 60% |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
| AC/DC Stick / Balance TIG |
|
| 34.0 |
|
|
|
|
|
| 350 |
|
| |||||
| Unbalance (70% Penetration#) AC TIG |
|
| 23.0 |
|
|
|
|
|
| 325 |
|
| ||||||
| 100% |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
| AC/DC Stick / Balance TIG |
|
| 32.0 |
|
|
|
|
|
| 300 |
|
| |||||
| Unbalance (70% Penetration#) AC TIG |
|
| 21.0 |
|
|
|
|
|
| 275 |
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
ADDITIONAL OUTPUT CAPACITY
Output Current
Range
2Amps DC
to
420Amps
Maximum Open
Circuit Voltage
(STICK AND TIG)
AC/DC OCV: 80
Type of Output
CC(Constant Current) AC/DC (GTAW) Stick (SMAW)
Auxiliary Power
5 Amp Circuit Breaker and grounded 220VAC Euro(Schuko) receptacle
#Exceeds NEMA Unbalanced Load Specification comparable for
*50/60HZ IEC Max. range exceeds 310A.