A-1

INSTALLATION

A-1

TECHNICAL SPECIFICATIONS - V200T TIG

INPUT - SINGLE PHASE ONLY

Standard

Voltage (1)

230/460/1/50/60

Duty Cycle (2)

20% Duty Cycle

60% Duty Cycle

100% Duty Cycle

Output Current

Range

1 - 200 A

Input Current at

Rated Output

45/23 A @ 200 A, 33/16 A @ 150 A,

25/13 A @ 120 A

RATED OUTPUT

Amps

200

150

120

OUTPUT

Maximum Open

Circuit Voltage

80 V

Code

Number

10463

Volts at Rated Amperes

28

26

25

Type of Output

DC

RECOMMENDED INPUT WIRE AND FUSE SIZES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

For DC TIG Welding at 200A/20% Duty Cycle

 

 

 

 

 

 

Based on the 1996 U.S. National Electrical Code

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Type 75°C

 

Input

 

 

 

Fuse

 

Input

 

 

Type 75°C

 

Copper Ground

 

Voltage /

 

 

(Super Lag)

 

Ampere

 

 

Copper Wire in

 

Wire in Conduit

 

phase/

 

 

or Breaker

 

Rating on

 

 

Conduit AWG

 

AWG (IEC)

 

Frequency

 

 

 

Size

 

Nameplate

 

 

(IEC) Sizes

 

Sizes

 

230/1/50/60

 

 

50

 

45

 

 

10 (5.2 mm2)

 

10 (5.2 mm2)

 

460/1/50/60

 

 

30

 

23

 

 

12 (4 mm2)

 

12 (4 mm2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PHYSICAL DIMENSIONS

Power Source

Height

10.04in. 255 mm

Width

7.48in. 190 mm

Depth

17.32in. 440 mm

Weight

Approx. 35 lbs. 16 kgs.

OPERATING TEMPERATURE

STORAGE TEMPERATURE

-20°C to +40°C

-25°C to +55°C

(1)Input voltage must be within ±10% of rated value.

(2)Duty Cycle is based on a 10 min. period.

INVERTEC V200-T

Page 8
Image 8
Lincoln Electric V200-T manual Installation, Technical Specifications V200T TIG