Indicator Descriptions
INDICATOR DEFINITION
OPERATION | PROGRAMMING |
INDICATION WHEN LIT
DURING NORMAL OPERATION
INDICATION WHEN LIT
DURING PROGRAMMING
24 VOLT INPUT |
| LOW VOLTAGE AC POWER IS PRESENT |
| |
POWER |
|
| ||
|
|
| ||
24 VOLT DC |
| LOW VOLTAGE DC POWER IS PRESENT |
| |
ACCY POWER |
|
| ||
|
|
| ||
|
| OPEN SIGNAL PRESENT FROM THE INTERNAL |
| |
OPEN |
| RECEIVER OR AN EXTERNAL DEVICE |
| |
|
| CONNECTED TO THE OPEN INPUT TERMINAL |
| |
CLOSE |
| CLOSE SIGNAL IS PRESENT FROM A DEVICE |
| |
| CONNECTED TO THE CLOSE INPUT TERMINAL |
| ||
|
|
| ||
STOP |
| STOP INPUT TERMINAL IS OPEN AND |
| |
| NOT CONNECTED TO COMMON |
| ||
|
|
| ||
PROGRAM |
|
| CONTROLLER IS IN PROGRAMMING MODE | |
REVERSE | DELAY SET | SIGNAL FROM REVERSING DEVICE IS PRESENT | SET REVERSE DELAY TIME | |
LOCKOUT | ALARM SET | CONTROLS AND OPERATOR ARE LOCKED OUT | SET RUN ALARM AND | |
BECAUSE OF EXISTING TROUBLE CONDITION | ||||
|
|
| ||
RADIO | LEARN | TRANSMITTERS CAN BE ENTERED INTO | ||
SIGNAL FROM A REMOTE CONTROL | MEMORY (UP TO 40 TRANSMITTERS) | |||
|
| |||
OPEN CURRENT | SET | MOTOR CURRENT HAS EXCEEDED THE | SET MAXIMUM OPEN CURRENT | |
OPEN CURRENT SETTING WHILE OPENING | ||||
|
|
| ||
|
| OPEN OBSTRUCTION TERMINAL CONNECTED |
| |
OPEN OBSTR | MGT 2 SET | TO COMMON BY BEAM OR SAFETY EDGE, OR | SET MGT #2 FUNCTION | |
|
| SIGNAL FROM MGT OBSTACLE TRANSMITTER |
| |
OPEN RELAY | LH/RH SET | OPEN RELAY IS ACTIVATED | SET | |
OPEN LIMIT | BRAKE DELAY | OPEN LIMIT SWITCH IS ACTIVATED |
| |
CLOSE CURRENT | SET | MOTOR CURRENT HAS EXCEEDED THE | SET MAXIMUM CLOSE CURRENT | |
CLOSE CURRENT SETTING WHILE CLOSING | ||||
|
|
| ||
|
| CLOSE OBSTRUCTION TERMINAL CONNECTED |
| |
CLOSE OBSTR | MGT 1 SET | TO COMMON BY BEAM OR SAFETY EDGE, OR | SET MGT #1 FUNCTION | |
|
| SIGNAL FROM MGT OBSTACLE TRANSMITTER |
| |
CLOSE RELAY | AUTO CLOSE SET | CLOSE RELAY IS ACTIVATED | SET | |
CLOSE LIMIT | AC DC SET | CLOSE LIMIT SWITCH IS ACTIVATED | SET MOTOR TYPE | |
SINGLE | SET | SINGLE TERMINAL CONNECTED TO COMMON | SET SINGLE BUTTON INPUT FUNCTION | |
BY AN EXTERNAL PUSHBUTTON OR RADIO | ||||
|
|
| ||
MAX RUN | SET | MAXIMUM RUN TIMER HAS BEEN EXCEEDED | SET MAXIMUM RUN TIME | |
COMM LINK | SET | DUAL OPERATOR CONNECTION DETECTED, |
| |
BLINKS IF CONNECTION HAS FAILED |
| |||
|
|
| ||
MAINT ALERT | SET | MAINTENANCE IS REQUIRED ON OPERATOR | SET MAINTENANCE ALERT CYCLE COUNT |
APEX FUNCTION DISPLAY INDICATIONS
"RL"
"PM"
"AC"
"RP"
"OC"
"CC"
"AD"
LEFT OR RIGHT HAND OPERATION
SINGLE OR
DUAL GATE
AUTO CLOSE
TIMER
RUN ALARM
MAXIMUM OPEN CURRENT
MAXIMUM CLOSE CURRENT
ADVANCED
PROGRAMMING
"RT"
"SB"
"SM"
"ST"
"AR"
"RD"
"BD"
MAXIMUM
RUN TIMER
SINGLE BUTTON INPUT SETUP
STAGGER
MODE
STAGGER
TIME
AUXILIARY
RELAY MODE
REVERSE
DELAY TIME
BRAKE
DELAY TIME
"CP"
"SP"
"CT"
"MA"
"MT"
"AT"
"RA"
CONSTANT
PRESSURE MODE
SHADOW LOOP
OPEN INHIBIT
RESET CYCLE
COUNT
MAINTENANCE ALERT TRIGGER
STOP POSITION
ENABLE
RADIO
ENABLE
LEARN
"TL" TRANSMITTERS
DELETE
"TD" TRANSMITTERS
LEARN MGT
"ML" TRANSMITTERS
ERASE MGT
"MD" TRANSMITTERS
MOTOR TYPE
"MO" SELECTION
RESET TO
"CL" FACTORY DEFAULTS
- 9 - | P1250 Revision X6 | |
|