Wiring Specifications
Refer to the following steps for details on power and accessory wiring for the operator.
WARNING
ALL AC ELECTRICAL CONNECTIONS TO THE POWER SOURCE AND THE OPERATOR MUST BE MADE BY A LICENSED ELECTRICIAN AND MUST OBSERVE ALL NATIONAL AND LOCAL ELECTRICAL CODES.
USE COPPER WIRE ONLY!
AC Power Wiring
1.Find the listing on this page corresponding to the model, voltage and horsepower rating of your operator.
2.The distance shown in the table is measured in feet from the operator to the power source. DO NOT EXCEED THE MAXIMUM DISTANCE. These calculations have been based on standard 115 V and 230 V supplies with a 10% drop allowable. If your supply is under the standard rating, the runs listed may be longer than what your application will handle, and you should not run wire too near the maximum distance for the gauge of wire you are using.
3.When
4.Wire length calculations are based on the National Electrical Code, Article 430 and have been carefully determined based on motor inrush, brake solenoids, and operator requirements.
5.Connect power in accordance with local codes. The green ground wire must be properly connected.
6.Wire insulation must be suitable to the application.
7.Electrical outlets are supplied in all 115 VAC models for convenience with occasional use or low power consumption devices only. If you choose to run dedicated equipment from these devices, it will decrease the distance for maximum length and the charts will no longer be accurate.
DC Control and Accessory Wiring
1.All control devices are now 24 VDC, which can be run up to 2000 feet with 14 AWG wire.
2.Control wiring must be run in a separate conduit from power wiring. Running them together may cause interference and faulty signals in some accessories.
3.A
MODEL VS-GSWG SINGLE PHASE POWER WIRING
VOLTS & HP | MAXIMUM DISTANCE (FEET) | WIRE GAUGE | ||
SINGLE | DUAL | |||
|
| |||
| 222 | 111 | 12 | |
115 VOLTS | 354 | 177 | 10 | |
566 | 283 | 8 | ||
900 | 450 | 6 | ||
| ||||
| 1430 | 715 | 4 | |
| 178 | 89 | 12 | |
115 VOLTS | 282 | 141 | 10 | |
450 | 255 | 8 | ||
716 | 358 | 6 | ||
| ||||
| 1140 | 570 | 4 | |
| 160 | 80 | 12 | |
115 VOLTS | 254 | 127 | 10 | |
406 | 203 | 8 | ||
646 | 323 | 6 | ||
| ||||
| 1026 | 513 | 4 | |
| 760 | 380 | 12 | |
208 VOLTS | 1200 | 600 | 10 | |
1924 | 962 | 8 | ||
3060 | 1830 | 6 | ||
| ||||
| 4864 | 2432 | 4 | |
| 604 | 302 | 12 | |
208 VOLTS | 958 | 478 | 10 | |
1526 | 763 | 8 | ||
2424 | 1212 | 6 | ||
| ||||
| 3856 | 1928 | 4 | |
| 544 | 272 | 12 | |
208 VOLTS | 864 | 432 | 10 | |
1374 | 686 | 8 | ||
2184 | 1092 | 6 | ||
| ||||
| 3476 | 1738 | 4 | |
| 894 | 447 | 12 | |
230 VOLTS | 1422 | 711 | 10 | |
2264 | 1132 | 8 | ||
3600 | 1800 | 6 | ||
| ||||
| 5724 | 2862 | 4 | |
| 710 | 355 | 12 | |
230 VOLTS | 1128 | 564 | 10 | |
1796 | 898 | 8 | ||
2852 | 1426 | 6 | ||
| ||||
| 4538 | 2269 | 4 | |
| 640 | 320 | 12 | |
230 VOLTS | 1016 | 508 | 10 | |
1616 | 808 | 8 | ||
2570 | 1285 | 6 | ||
| 4090 | 2045 | 4 | |
| ||||
MODEL | ||||
VOLTS & HP | MAXIMUM DISTANCE (FEET) | WIRE GAUGE | ||
SINGLE | DUAL | |||
|
| |||
208 VOLTS | 1142 | 571 | 12 | |
1816 | 908 | 10 | ||
2890 | 1445 | 8 | ||
| ||||
208 VOLTS | 920 | 460 | 12 | |
1464 | 732 | 10 | ||
2330 | 1165 | 8 | ||
| ||||
208 VOLTS | 714 | 357 | 12 | |
1136 | 568 | 10 | ||
1804 | 902 | 8 | ||
| ||||
230 VOLTS | 1344 | 672 | 12 | |
2137 | 1069 | 10 | ||
3400 | 1700 | 8 | ||
| ||||
230 VOLTS | 1084 | 542 | 12 | |
1723 | 862 | 10 | ||
2741 | 1371 | 8 | ||
| ||||
230 VOLTS | 840 | 420 | 12 | |
1336 | 668 | 10 | ||
2124 | 1062 | 8 | ||
| ||||
460 VOLTS | 3841 | 1921 | 12 | |
6106 | 3053 | 10 | ||
9712 | 4856 | 8 | ||
| ||||
460 VOLTS | 3279 | 1640 | 12 | |
5212 | 2606 | 10 | ||
8291 | 4146 | 8 | ||
| ||||
460 VOLTS | 2689 | 1345 | 12 | |
4274 | 2437 | 10 | ||
6798 | 3399 | 8 | ||
|
- 2 - | P1250 Revision X6 | |
|