Image 35
RC5 Amplifier

 

 

 

 

 

 

 

 

Number

Name

Description

Values

 

 

 

 

 

 

 

 

U7

RC5 Amplifier

Configures the amplifier address.

0

= 16

 

 

 

Address

Leave at 16 for KOLEKTOR handset.

1

= 19

 

 

 

 

 

 

 

 

 

U8

Enable Unity Gain

Enables an input as a unity gain input.

0

= Disabled

 

 

 

For use with an external surround sound

1

= Input 1

 

 

 

processor.

2

= Input 2

 

 

 

 

3

= Input 3

 

 

 

 

4

= Input 4

 

 

 

 

5

= Input 5

 

 

 

 

6

= Input 6

 

 

 

 

7

= Input 7

 

 

 

 

8

= Input 8

 

 

 

 

9

= Input 9

 

 

 

 

10 = Input 10

 

 

 

 

 

 

 

 

U9

Default Display

Defines the display after the time-out

0

= Maintain

 

 

 

period specified by U10. After a further

1

= Volume

 

 

 

time-out period U2 defines the display.

2

= Balance

 

 

 

 

3

= Bass

 

 

 

 

4

= Treble

 

 

 

 

5

= Source name

 

 

 

 

6

= Source number

 

 

 

 

7

= Source name/number

 

 

 

 

 

 

 

 

U10

Time-Out Period

Specifies the display time-out period, used

0

= 2 seconds

 

 

 

by U9.

1

= 5 seconds

 

 

 

 

2

= 10 seconds

 

 

 

 

3

= 15 seconds

 

 

 

 

4

= 20 seconds

 

 

 

 

 

 

 

 

U11

Volume Control

Defines how volume and balance change on

0

= Fade volume/balance

 

 

 

MUTE and source switching.

1

= Step volume/balance

 

 

 

 

 

 

 

 

U12

RS232 Command

Enables/disables RS232 commands.

0

= Disable

 

 

Interface

 

1

= Enable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

25