1 Service
Parameter table A - Boiler Operation (continued)
Table 1D_(continued from previous page) This table lists SMART SYSTEM control module parameters and where to access them for boiler operation ONLY
CONTROL ANTI- CASCADE MODES CYCLING
BMS
SERVICE NOTIFICATION PUMPS
Menu | Sub | Description | See | User Access | Installer Access | |||
Item | Page | Display | Modify | Display | Modify | |||
| 1 | 21 | No | No | Yes | Yes | ||
G | 2 | 21 | No | No | Yes | Yes | ||
3 | Minimum On/Off Delay Stages 1, 3 (On/off Delay) | 21 | Yes | Yes | Yes | Yes | ||
| ||||||||
| 4 | Next On Delay | 21 | Yes | Yes | Yes | Yes | |
| 1 | SH Controlling Sensor (SH Cnt Sensor) | 22 | No | No | Yes | Yes | |
| 2 | Enable Input (Active / Inactive) | 22 | No | No | Yes | Yes | |
| 3 | BMS Input (Active / Inactive) | 22 | No | No | Yes | Yes | |
H | 4 | Cascade (Active / Inactive) | 22 | No | No | Yes | Yes | |
| 5 | Sequencer | 22 | No | No | Yes | Yes | |
| 6 | ModBus (Active / Inactive) | 22 | No | No | Yes | Yes | |
| 7 | ModBus Timeout (ModBus Time) | 22 | No | No | Yes | Yes | |
| 1 | Boiler Address (Blr Adress) | 23 | No | No | Yes | Yes | |
I | 2 | Maximum Cascade Setpoint (Max Casc Stpt) | 23 | Yes | Yes | Yes | Yes | |
3 | Cascade Offset (Cas Offset) | 23 | No | No | Yes | Yes | ||
| ||||||||
| 4 | Cascade Differential (Cas Different) | 23 | No | No | Yes | Yes | |
| 1 | BMS Type | 23 | No | No | Yes | Yes | |
| 2 | Voltage at Minimum (V at Min) | 23 | No | No | Yes | Yes | |
| 3 | Voltage at Maximum (V at Max) | 23 | No | No | Yes | Yes | |
| 4 | Minimum Power (Min Power) | 23 | No | No | Yes | Yes | |
J | 5 | Maximum Power (Max Power) | 23 | No | No | Yes | Yes | |
| 6 | Minimum Setpoint (Min Setpoint) | 23 | No | No | Yes | Yes | |
| 7 | Maximum Setpoint (Max Setpoint) | 24 | No | No | Yes | Yes | |
| 8 | Voltage to Start CFH (V at Start) | 24 | No | No | Yes | Yes | |
| 9 | Voltage Differential Stop CFH (V Diff Stop) | 24 | No | No | Yes | Yes | |
| 1 | System Pump Delay (Sys Pump Dlay) | 24 | No | No | Yes | Yes | |
K | 2 | SH Pump Delay (SH Pump Delay) | 24 | No | No | Yes | Yes | |
3 | DHW Pump Delay (DHW Pump Dlay) | 24 | No | No | Yes | Yes | ||
| ||||||||
| 4 | System Pump Mode (Sys Pump Mode) | 24 | No | No | Yes | Yes | |
| 1 | Service Interval Time (months) (Srv Int Time) | 24 | No | No | Yes | Yes | |
|
|
|
|
|
|
|
| |
| 2 | Service Interval Run (Srv Int Run) | 24 | No | No | Yes | Yes | |
L | 3 | Service Interval Operation (hours) (Srv Int Op) | 24 | No | No | Yes | Yes | |
| 4 | Reset Service | 24 | No | No | Yes | Yes | |
| 5 | Accept Personality Plug (Accept PPlug) | 24 | No | No | Yes | Yes | |
|
|
|
|
|
|
|
|
14