Lochinvar 81 - 286 operation manual Ratings, Knight Boiler =B=R Rating

Models: 81 - 286

1 80
Download 80 pages 14.57 Kb
Page 7
Image 7

Installation & Operation Manual

Ratings

Knight Boiler

I=B=R Rating

 

 

Input

Gross

Net

 

 

Output

Model Number

 

MBH

I=B=R

 

MBH

 

 

 

 

 

Ratings

 

 

 

 

 

Water,

Note: Change “N” to

 

(Note 5)

 

MBH

“L” for L.P. gas models.

 

 

 

 

 

 

 

 

 

 

 

 

Min

 

Max

(Note 2,7)

(Note 3,7)

KBN081

16

 

80

72

63

 

 

 

 

 

 

KBN106

21

 

105

94

82

 

 

 

 

 

 

KBN151

30

 

150

135

117

 

 

 

 

 

 

KBN211

42

 

210

190

165

 

 

 

 

 

 

KBN286

57

 

285

260

226

 

 

 

 

 

 

Other Specifications

Boiler

 

 

 

Vent

 

 

Air

Size

Water

Water

Gas

 

Size

 

Content

Connections

Connections

(Note 4)

Gallons

 

 

 

 

 

 

 

 

0.6

1"

1/2"

3"

3"

 

 

 

 

 

0.7

1"

1/2"

3"

3"

 

 

 

 

 

1.3

1"

1/2"

3"

3"

 

 

 

 

 

1.7

1"

1/2"

3"

3"

 

 

 

 

 

2.4

1-1/4"

3/4"

4"

4"

 

 

 

 

 

NOTICE

Maximum allowed working pressure is located on the rating plate.

 

 

8. Knight boilers comply with the requirements of CSD-1

Notes:

 

 

Section CW-400 requirements as a temperature operation

1. As an Energy Star Partner, Lochinvar has determined that

control. The manual reset high limit provided with the

Knight boilers meet the Energy Star guidelines for energy

Knight is listed to UL353.

efficiency.

2.The ratings are based on standard test procedures prescribed by the United States Department of Energy.

3.Net I=B=R ratings are based on net installed radiation of

sufficient quantity for the requirements of the building and nothing need be added for normal piping and pickup. Ratings are based on a piping and pickup allowance of 1.15.

4.

Knight boilers require special gas venting. Use only

UNIT EQUIPPED FOR

 

the vent materials and methods specified in the Knight

HIGH ALTITUDE

 

Installation and Operation Manual.

 

 

5.

Standard Knight boilers are equipped to operate from sea

3,000 FT. TO 12,000 FT.

 

 

level to 4,500 feet only with no adjustments. The boiler

 

 

will de-rate by 4% for each 1,000 feet above sea level up to

 

 

4,500 feet.

 

6.

High altitude Knight boilers are equipped to operate

 

 

from 3,000 to 12,000 feet only with no field adjustments.

 

 

The boiler will de-rate by 2% for each 1,000 feet above

 

 

3,000 feet. High altitude models are manufactured with

 

 

a different control module for altitude operation, but the

 

 

operation given in this manual remains the same as the

 

 

standard boilers. A high altitude label (as shown in FIG. A)

Figure A High Altitude Label Location

 

is also affixed to the unit.

 

7.

Ratings have been confirmed by the Hydronics Institute,

7

 

Section of AHRI.

 

Page 7
Image 7
Lochinvar 81 - 286 operation manual Ratings, Knight Boiler =B=R Rating