4 Sidewall direct venting

Sidewall termination – optional concentric vent

Figure 4-9Concentric Vent Dimensional Drawing -

Figure 4-10 Concentric

Vent

Dimensional

Drawing

-

Models 81 - 211

Model 286

 

 

 

 

 

 

"A"

 

 

 

 

"B" DIA.

 

 

 

 

 

"C" DIA.

 

 

 

 

 

 

3"

"D"

 

 

 

 

 

 

 

 

 

(76 MM)

 

 

 

 

 

 

 

 

"E"

 

"G"

 

"H" DIA.

 

 

 

"B" DIA. PVC

 

 

"F"

 

 

VENT / EXHAUST

 

 

 

 

NOTICE

Instead of cementing the smaller pipe

to the rain cap, a field-supplied stainless

 

steel screw may be used to secure the

 

two (2) components together when field

 

disassembly is desired for cleaning (see

 

FIG. 4-11).

6.Install the Y concentric fitting and pipe assembly through the structure’s hole from an inside wall.

NOTICE

Do not allow insulation or other materials to

accumulate inside the pipe assembly when

 

 

installing through the hole.

￿WARNING

￿WARNING

When using the alternate screw assembly method, drill a clearance hole in the rain cap and a pilot hole in the vent pipe for the screw size being used. Failure to drill adequate holes may cause cracking of PVC components, allowing combustion products to be recirculated. Failure to follow this warning could result in personal injury or death.

Do not operate the appliance with the rain cap removed or recirculation of combustion products may occur. Water may also collect inside the larger combustion air pipe and flow to the burner enclosure. Failure to follow this warning could result in product damage or improper operation, personal injury, or death.

7.Install the rain cap and small diameter pipe assembly into the Y concentric fitting and large pipe assembly from an outside wall. Ensure small diameter pipe is bottomed and cemented in the Y concentric fitting for #CVK3003 installations and fastened tightly into the rubber adapter for #CVK3007 installations.

8.Secure the assembly to the structure as shown in FIG. 4-12 using field-supplied metal strapping or equivalent support material.

NOTICE

Ensure termination location clearance

dimensions are as shown in FIG. 4-6.

 

If assembly needs to be extended to allow

NOTICE

sidewall thickness requirement, the two (2)

 

 

pipes supplied in the kit may be replaced

 

by using the same diameter, field-supplied

 

SDR-26 PVC (D2241) pipe for CVK3003

Figure 4-11Rain Cap to Vent Pipe Alternate Assembly

 

and standard schedule 40 PVC for CVK3007.

 

Do not extend dimension D* more than 60

 

inches (see FIG.’s 4-9 and 4-10).

 

If assembly depth needs to be reduced,

NOTICE

dimension D can be as short as possible.

 

26

Page 26
Image 26
Lochinvar 81 - 286 operation manual Concentric

81 - 286 specifications

Lochinvar 81 - 286 is a state-of-the-art boiler recognized for its efficiency and reliability in both residential and commercial applications. This high-performance heating solution is designed to meet the diverse needs of users while adhering to modern environmental standards.

One of the standout features of the Lochinvar 81 - 286 is its advanced condensing technology. This allows the unit to harness more heat from the combustion gases, significantly boosting its thermal efficiency. With an impressive efficiency rating of over 95%, users can expect lower energy bills and reduced carbon emissions, making this boiler an environmentally friendly choice.

The Lochinvar 81 - 286 incorporates a robust stainless steel heat exchanger that guarantees durability and longevity. This corrosion-resistant material not only prolongs the unit's life but also ensures consistent performance over time. Additionally, the heat exchanger’s design facilitates optimal heat transfer, further enhancing the boiler's efficiency.

In terms of control, the Lochinvar 81 - 286 features a user-friendly control interface that simplifies operation. The boiler is equipped with advanced modulation capabilities, allowing it to adjust its output based on real-time heating demands. This responsiveness reduces energy waste and optimizes comfort levels within the space it serves.

The boiler also supports a variety of installation configurations, providing flexibility for different building layouts. Its compact design allows for easy installation in restricted spaces, while versatile venting options facilitate integration into various systems.

Safety is a paramount consideration in the design of the Lochinvar 81 - 286. The unit comes with integrated safety features such as a built-in diagnostic system that alerts users to any potential issues before they escalate. This proactive technology helps in maintaining seamless operation and reducing downtime.

Finally, the Lochinvar 81 - 286 is compliant with the latest regulations and industry standards, ensuring that it meets the expectations of both consumers and environmental agencies. With its impressive combination of efficiency, durability, and advanced technology, the Lochinvar 81 - 286 stands out as a top choice for anyone seeking a high-performance heating solution. This boiler not only addresses the immediate needs of heating but also supports long-term sustainability initiatives, proving to be a wise investment for the future.