Stove Installation (for qualified installers only) | 15 |
Exterior Factory Built Chimney
NOTE:
Exterior chimneys are subject to greater moisture and creosote accumulation due to the lower temperatures. An insulated chase will reduce these accumulations (the proper clearances to the chimney must be maintained)
Chimney Cap |
|
| Follow the chimney | |
|
| manufacturer's | ||
(See the section "Chimney |
|
| ||
| } | instructions and | ||
Termination Requirements" | ||||
clearances for roof | ||||
for more details) |
| |||
| penetrations. A storm | |||
|
| |||
Chimney Sections | collar and flashing are | |||
required (some | ||||
|
| |||
Minimum Air Space to |
| require a radiation | ||
Combustibles (See |
| shield). | ||
Chimney Manufacturer's | Wall Bands | Minimum 15' | ||
Instructions - usually 2") | and | |||
Maximum 33' | ||||
| Supports | |||
|
|
| ||
Min. 18" |
| Insulated Tee | ||
clearance to |
| (with cleanout ) | ||
ceiling | } | Follow the chimney | ||
| ||||
| manufacturer's | |||
Chimney Connector | instructions and | |||
|
| |||
|
| clearances for wall | ||
|
|
| ||
|
|
| penetrations. A | |
|
|
| wall radiation shield | |
Floor Protection |
|
| (thimble) is | |
(See "Floor |
| Stove Clearances | required. | |
Protection |
|
| ||
| (See the section "Stove | Optional | ||
Requirements" |
| |||
| Placement Requirements" | insulated | ||
for details) |
| |||
| for more details) | chase | ||
|
|
Hearth Stove
Positive
Connection
NOTE:
Most
| Figure 12 |
| Cap and flashing |
| prevents water from |
NOTE: The entire fireplace and | entering |
| |
chimney must be clean, undamaged, |
|
and meet all local building codes |
|
(UBC, etc.). Damage must be |
|
repaired prior to installation. The |
|
chimney must be 15' to 33' tall. |
|
| The liner must be |
| stainless steel connector |
| or flexible vent. Follow |
| the liner manufacturer's |
| instructions for installation |
| and support. |
Combustible |
|
Mantle |
|
Min. 18" | Airtight Insulated |
| |
| |
| Remove damper |
| or wire it open |
Floor Protection |
|
(See the section |
|
"Floor Protection |
|
Requirements" | See the section |
for more details) | "Stove Placement |
| Requirements" for |
| minimum clearances |
| required. |
| Figure 13 |
© Travis Industries | 4040608 |