SAFETY NOTICE:

Please read this entire manual before you install and use your new room heater. Failure to follow instructions may result in property damage, bodily injury, or even death. Contact local building or fire officials about restrictions and installation inspection requirements in your area.

Planning The Installation

We suggest that you have an authorized Travis Industries dealer install your fireplace insert. If you install the fireplace insert yourself, your authorized dealer should review your installation plans.

Check with local building officials for any permits required for installation of this fireplace insert and notify your insurance company before proceeding with installation.

Preparation for Installation

Check for damage to the exterior of the fireplace insert (dents should be reported, scratches can be fixed by applying touch up paint).

Check the interior of the firebox (replace cracked firebrick and make sure baffle is in place).

The fireplace insert can be lightened by removing the firebricks and baffle (pg 25) - replace before operation.

Additional Accessories Needed for Installation

1Door Shell (Black 99300195 Brass 99300196 or Pewter 99300197 - see pg 29)

2 Surround Panels (see page 31)

Installation Considerations

Installation Type

Considerations

 

 

Insert with Positive Flue (Full Reline)

• Utilizes existing masonry or zero clearance fireplace

(Page 12)

• Provides best draft

• Easiest to clean

 

Insert with Direct Connect Flue

• Utilizes existing masonry or zero clearance fireplace

(Page 12 and 13)

• Provides good draft

• Requires fireplace block-off plate - see page 11

 

Insert with Face Seal Connection

• Utilizes existing masonry fireplaces with cross section

(Page 13)

of 28" to 144" (not approved for zero clearance
fireplaces)

NOTE: Before installing verify with local building

• Provides okay draft

officials that this type of installation is

• Easiest to install

approved in your area.

• Requires the optional surround panels and insulation

 

(see "Surround Panels" on page 31).