Lopi Revere Stove Installation for qualified installers only, Insert with Face Seal Connection

Models: Revere

1 34
Download 34 pages 25.3 Kb
Page 13
Image 13
Insert with Direct Connection (Z.C. Fireplace)

Stove Installation (for qualified installers only)

13

Insert with Direct Connection (Z.C. Fireplace)

NOTE:

Direct connections require installation of an airtight block-off plate or damper adapter (see "Block-off Plate Installation" on page 11)

NOTE: This installation may be used with a masonry or zero clearance fireplace. This illustration depicts a zero clearance insert, all requirements in the section "Zero Clearance Fireplace Requirements" must be fulfilled prior to installation.

Combustible MantleInsert with Face Seal Connection

Surround PanelsManual background

See the section Manual backgroundManual background "Insert PlacementManual background Requirements" forManual backgroundManual backgroundManual background minimum clearancesManual backgroundManual background and hearth required.Manual backgroundManual backgroundManual background

Stainless steel chimney connector must Extend 1' past the block-off plate.

Manual background Damper must be

Block-off plate or damper adapter

Manual background Z.C. (Metal) firebox

Insert with Face Seal Connection

NOTE:

Face seal connections require installation of the surround panels and insulation (see the "Surround Panel Installation" on page 32)

Optional

Telescoping Legs

NOTE: This installation may be used with a masonry fireplace only. The requirements in the section "Masonry Fireplace Requirements" must be fulfilled prior to installation.

Flue

Liner

Combustible Mantle

Surround Panels with insulation (see "Surround Panels" installation instructions in the back of

the manual)

See the section "Insert

Placement Requirements"

for minimum clearances

and hearth required.

No modification to the firebox of the z.c. fireplace is allowed.

NOTE: It is recommended your chimney have a minimum 28 and a maximum of 144 square inch cross- sectional area to use a face seal connection, otherwise your chimney maynot have sufficient draw for the fireplace insert to operate correctly.

Airtight Insulated

Clean-Out

Remove damper or wire it open