Louisville Tin and Stove W502F W255F Lighting Instructions, For Your Safety Read Before Lighting

Models: W505F W256F W251F W501F W252F W356F W502F W255F W355F W351F W352F W506

1 20
Download 20 pages 48.1 Kb
Page 10
Image 10
LIGHTING INSTRUCTIONS

LIGHTING INSTRUCTIONS

MODELS: W255F, W256F / W355F, W356F / W505F, W506F

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing

property damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these in- structions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS:

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING INSTRUCTIONS

1.STOP! Read the information on the safety label.

2.Set thermostat to it’s lowest setting.

3.Open cabinet door.

4.Depress and turn gas control knob clockwiseFOR YOUR SAFETY READ BEFORE LIGHTING to “OFF”.

Gas Control Knob

 

Manifold

 

Pressure Tap

Pilot Adjustment

Internal Manifold

Screw Cap

Pressure Regulator

 

NOTE: Knob cannot be turned from “PILOT” to “OFF” unless knob is pushed in slightly. Do not force.

5.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the information on the safety label. If you don’t smell gas, go to the next step.

6.Locate the pilot. (Follow metal pilot tube from gas control).

7.

Turn gas control knob counterclockwise

to

 

“PILOT”.

 

Pilot is located on side of burner

8.Push gas control knob and hold in. Immediately light the pilot with a match. Continue to hold the gas control knob in for about one (1) minute after the pilot is lit. Release gas control knob and it will pop back up. Pilot should remain lit. If pilot goes out, repeat steps 4 through 8.

If knob does not pop up when released, STOP and immediately call your service technician or gas supplier.

If the pilot will not stay lit after several tries, turn the gas control knob to “OFF” and call your service technician or gas supplier.

9.

Turn gas control knob counterclockwise

to

 

“ON”.

 

10.Close the cabinet door.

11.Set thermostat to desired setting.

property damage, personal injury or loss of life. TO TURN OFF GAS TO APPLIANCE

1.

Set the thermostat to it’s lowest setting.

3.

Push in gas control knob slightly and turn clockwise

2.

Open cabinet door.

 

to “OFF”. Do not force.

 

 

4.

Close cabinet door.

Page 10

Page 10
Image 10
Louisville Tin and Stove W502F W255F, W506, W351F, W355F, W356F Lighting Instructions, For Your Safety Read Before Lighting