Louisville Tin and Stove W501F W252F, W506, W351F Symptom, Possible Causes, Corrective Action

Models: W505F W256F W251F W501F W252F W356F W502F W255F W355F W351F W352F W506

1 20
Download 20 pages 48.1 Kb
Page 15
Image 15

TROUBLE SHOOTING CHART for qualified serviceman - MAIN BURNER

SYMPTOM

POSSIBLE CAUSES

 

CORRECTIVE ACTION

Flame too large

1.

Defective operator section of gas valve.

1.

Replace complete valve.

 

2.

Burner orifice too large.

2.

Check with local gas company for proper

 

 

 

 

orifice size and replace.

 

3.

If installed above 2,000 ft.

3.

Refer to orifice chart, Page 3.

Flame pops back

1.

Too much primary air.

1.

Adjust air shutter. (See Page 12).

Noisy Flame

1.

Too much primary air.

1. Adjust air shutter. (See Page 12).

 

2.

Noisy pilot.

2.

Reduce pilot gas with adjusting screw on

 

 

 

 

combination gas control valve.

 

3.

Burr in orifice (if it whistles or resonates).

3.

Remove burr or replace orifice (Do not enlarge orifices).

 

4.

Excessibe gas input.

4.

See “Flame Too Large” above.

Yellow tip flame

1.

Too little primary air.

1.

Adjust air shutter. (See Page 12).

(some yellow tipping

2.

Clogged main burner ports.

2.

Clean main burner ports. (Do not enlarge ports).

on L.P. gas is

3.

Clogged draft hood.

3.

Clean draft hood.

permissible)

4.

Linted up air shutter.

4.

Check for dust or lint at air mixer opening and

 

 

 

 

around the shutter. Clean as necessary.

Floating Flame

1.

Blocked venting.

1.

Clean flue passageways to remove blockage.

 

2.

Insufficient primary air.

2.

Adjust air shutter to increase primary air supply.

 

 

 

 

(See Page 12).

Gas Odor

1.

Gas leak.

1.

Shut off gas service immediately. Check

 

 

 

 

piping. Call gas company. (See Page 1).

 

2.

Chimney or flue obstruction.

2.

Clean flue.

 

3.

Drafts around appliance.

3.

Eliminate drafts.

Delayed Ignition

1.

Pilot flame too small.

1.

Check pilot orifice, increase pilot gas flow

 

 

 

 

if necessary by adjusting inlet pressure.

 

2.

Burner ports clogged near pilot.

2.

Clean burner ports (Do not enlarge ports).

 

3.

Low gas pressure.

3.

Check gas supply pressure.

 

4.

Pilot decreases in size when main burners

4.

Supply piping is inadequately sized. Consult local

 

 

come on.

 

gas utility or competent installer.

 

5.

Air shutter open too far.

5.

Close air shutter to proper setting as outlined in these

 

 

 

 

instructions (slight yellow tipping is allowable on

 

 

 

 

L.P. Gas). (See Page 12).

 

6.

Drafts around appliance.

6.

Eliminate drafts.

 

7.

Bad venting.

7.

See “Venting”.

Failure to Ignite

1.

Main gas off.

1.

Open all manual gas valves.

 

2.

Defective gas valve.

2.

Replace gas valve.

Condensation of

1.

Improper venting.

1.

See “Venting”.

water vapor

 

 

 

 

Burner won’t

1.

Defective or sticking automatic valve.

1.

Clean or replace valve.

turn off

2.

Excessive gas pressure (The supply gas

2.

To correct this situation contact the utility

 

 

pressure must not exceed 1/2 psi or 14”

 

supplying the gas.

 

 

water column).

 

 

Incorrect gas input

1.

Gas input not checked.

1.

Re-check gas input.

 

2.

Clogged orifice.

2.

Check orifice for clogging. If clogged,

 

 

 

clean out the hole carefully with a smooth wood toothpick.

 

 

 

(Do not in any way enlarge or distort it).

Not enough heat

1.

Appliance undersized.

1.

This is especially true when a dwelling or room is

 

 

 

 

enlarged. Have the heat loss calculated and compare

 

 

 

 

to the appliance output (70% of input). Your gas

 

 

 

 

company or installer can supply you with this

 

 

 

 

information. If appliance is undersized, replace with

 

 

 

 

correct size unit.

 

2.

Temperature dial set too low. (Bulb

2.

Raise setting of Temperature Dial. See

 

 

type valves).

 

“Lighting and Shutting Down Instructions”.

 

3.

Incorrect supply pressure.

3.

Check supply pressure as outlined above.

Too much heat

1.

Temperature dial set too high.

1.

Lower setting of temperature dial. See “Lighting

 

 

 

 

and Shutting Down Instructions”.

 

2.

Combination control valve sticks open.

2.

Replace combination control valve.

 

 

 

 

 

Page 15

Page 15
Image 15
Louisville Tin and Stove W501F W252F, W506, W502F W255F, W351F, W355F, W505F W256F Symptom, Possible Causes, Corrective Action