5-9 DSC Test Reply (TEST REPLY)

You can respond to incoming DSC TEST calls with an automatic response or with a manual response.

MANUAL manual response is required, press ENT to confirm or press EXIT to cancel.

• AUTO

automatically replies after a 10 second delay with an ACK to any incoming

 

 

DSC TEST call.

DSC SETUP

TEST REPLY

LL REPLY

AUTO

AUTO SWITC

 

MANUAL

TEST REPLY

 

 

TIMEOUT

5-10 Set the inactivity timer (TIMEOUT)

You can set the inactivity timer with the following options:

AUTOMATED you can set the inactivity timer to automatically timeout after a period of inactivity for the following two categories: NON-DISTRESS or

DISTRESS.

Timeout options are:

DISTRESS: NO TIMEOUT; 5 MINS; 10 MINS (default is NO TIMEOUT)

NON-DISTR: NO TIMEOUT; 10 MINS; 15 MINS (default is 15 MINS)

NON AUTO you can set the inactivity timer to exit any non-automated procedure activity.

Timeout options are:

NO TIMEOUT; 10 MINS; 15 MINS (default is 10 MINS)

Note: If NO TIMEOUT is selected, then you must press the EXIT key to exit the procedure.

Example: to set a 10 minute TIMEOUT for non-automated functions:

1.Select TIMEOUT, then select NON AUTO

2.Select desired timeout period: NO TIMEOUT, 10 MINS or 15 MINS

DSC SETUP

TIMEOUT

NON AUTO

LL REPLY

AUTOMATED

NO TIMEOUT

AUTO SWITC

 

NON AUTO

10 MINS

TEST REPLY

 

 

15 MINS

TIMEOUT

 

 

 

In this example, 10 MINS has been selected, meaning the radio will exit any non-automated procedure after a period of 10 minutes of non-activity.

42

Lowrance - Link-8 Operation Instructions