Chapter 5 Fault Management

Viewing Traps

Traps that are sent by the agent to its managers may be viewed in two places:

In the Port Configuration dialog box.

In the Event Log.

Viewing Traps in a Dialog Box

A list of traps sent by the agent is maintained by the management application. The list can be viewed in a dropdown list box in the Port Configuration dialog box of the appropriate port.

Viewing Traps in the Event Log

HP OpenView maintains a list of all traps sent by the agents on the network. They may be viewed by opening the Event Log from the HP OpenView network map window. For a full description of the Event Log, refer to the HP OpenView Administrator’s Guide.

Assigning Severity Degrees (UNIX and NT-OV Only)

Management applications, using the Event Configuration application, allow you to set fault severity degrees system-wide, (for all devices on the network simultaneously), or for specific devices (per IP). If the system-wide setting and an individual device's setting disagree, the individual device's setting takes precedence.

For more information refer to Severity Degrees in The Reference Guide.

Accessing Severity Degrees

Only events whose category is “Status Events” affect the device’s status. Events in this category may be found under the enterprises Lannet (.1.3.6.1.4.1.81) and CajunM770 (.1.3.6.1.4.1.81.17.1.15).

Severity degree settings may be accessed from the Event Configuration application. To open the Event Configuration application:

1From the umbrella management application, open the Tools menu and select

Lucent ! Event Configuration.

OR

Open the Options menu and select Event Configuration.The Event Configuration application appears.

Editing Severity Degrees

Severity degrees may be changed for faults on a system-wide basis, or for specific devices (per IP).