Unprotected Surfaces

Vermont Castings Resolute Acclaim

Distance from the Center of the Flue Collar to the Wall in Top-Exit Installations

The information on this page is helpful in planning stove placement for top-exiting installations, particularly those installations with chimneys that pass through the ceiling. However, this is not a clearance chart. Final stove clear- ances must adhere to the guidelines stated in the Clearance Chart on Page 8.

Resolute Acclaim: WITHOUT Stove and Chimney Connector Heat Shields

 

 

Unprotected Surfaces

 

Protected Surfaces

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Corner

 

 

 

 

Corner

 

Parallel Installations

Installations**

Parallel Installations

 

Installations**

 

 

 

 

 

 

 

 

 

 

 

 

Side (A)

 

Rear (B)

Corner (C)

Side (D)

 

Rear (E)

 

Corner (F)

 

 

 

 

 

 

 

 

 

 

 

 

27¹⁄₂”

 

26”

25¹⁄₂”

20¹⁄₂”

 

15”

 

18¹⁄₂”

 

(700mm)

 

(660mm)

(650mm)

(520mm)

 

(380mm)

 

(470mm)

 

 

 

 

 

 

 

 

 

 

 

Protected Surfaces A Manual background

*

B

C

*Manual background

D Manual background

E

F

ST608

*This distance, from the center of the flue collar to the front edge of the hearth, is the same for all installations on this page: 35” in the United States and 37” (940mm) in Canada.

Resolute Acclaim: WITH Stove and Chimney Connector Heat Shields

 

 

Unprotected Surfaces

 

Protected Surfaces

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Corner

 

 

 

 

Corner

 

Parallel Installations

Installations**

Parallel Installations

 

Installations**

 

 

 

 

 

 

 

 

 

 

 

 

Side (A)

 

Rear (B)

Corner (C)

Side (D)

 

Rear (E)

 

Corner (F)

 

 

 

 

 

 

 

 

 

 

 

 

27¹⁄₂”

 

17”

25¹⁄₂”

20¹⁄₂”

 

11”

 

18 ¹⁄₂”

 

(700mm)

 

(430mm)

(650mm)

(520mm)

 

(280mm)

 

(470mm)

 

 

 

 

 

 

 

 

 

 

 

Manual background A Manual background

B

C

Manual background D

E

F

ST608a

**To locate center of flue collar for corner installation, add 10¹⁄₂” (270mm) to the clearance distance from stove corner to wall. Mark off the resulting distance from the corner along both walls. Next, measure the same distance from these two points out from the walls. These last two measurements will meet at a point representing the center of the flue collar. Refer to the diagrams above.

2000893

15