Majestic Appliances 2490 Resolute Acclaim Clearance Chart, Unprotected Surface, Protected Surface

Models: 2490

1 32
Download 32 pages 51.14 Kb
Page 12
Image 12
Resolute Acclaim Clearance Chart

Vermont Castings Resolute Acclaim

Resolute Acclaim Clearance Chart

 

Unprotected Surface

 

Protected Surface

 

Parallel Installation

 

 

Corner

 

Parallel Installation

 

Corner

 

 

Installation

 

 

Installation

 

 

 

 

 

 

 

 

 

Stove Clearance

Side

Rear

 

 

 

Corner

 

Side

Rear

 

Corner

No heat shields

(A) 15”

(B) 24”

 

 

(C) 15”

 

(D) 8”

(E) 13”

 

(F) 8”

(380mm)

(610mm)

 

 

(380mm)

 

(200mm)

(330mm)

 

(200mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Top exit, rear heat

(G) 15”

(H) 24”

 

 

(I) 15”

 

(J) 8”

(K) 13”

 

(L) 8”

shield only 1

 

 

 

 

(380mm)

(610mm)

 

 

(380mm)

 

(200mm)

(330mm)

 

(200mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rear exit, rear heat

(M) 15”

(N) 10”

 

 

N/A

 

(O) 8”

(P) 7”

 

N/A

shield only

(380mm)

(250mm)

 

 

 

 

(200mm)

(180mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Top exit, rear h.s.,

(Q) 15”

(R) 15”

 

 

(S) 15”

 

(T) 8”

(U) 9”

 

(V) 8”

single-wall connector,

(380mm)

(380mm)

 

 

380mm)

 

(200mm)

(230mm)

 

(200mm)

connector shields 1,2

 

 

 

 

 

 

 

 

 

 

 

 

Top exit, rear h.s.,

(Q) 15”

(R) 17”

 

 

(S) 15”

 

 

*

 

 

 

double-wall

(380mm)

(432mm)

 

 

380mm)

 

 

 

 

 

 

connector1,3

 

 

 

 

 

 

 

 

 

 

 

 

Chimney Connector

 

 

 

 

 

 

 

 

 

 

 

 

Clearance

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No Heat Shields

 

23” (580mm)

 

 

 

12” (300mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

Chimney connector

 

 

 

 

 

 

 

 

 

 

 

 

heat shields2

 

14”

(360mm)

 

 

 

8” (200mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

Double-wall connector3

 

16”

(410mm)

 

 

 

*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Front Clearance

 

 

 

 

 

 

 

 

 

 

 

 

to Combustibles**

 

 

 

All Installations

48” (1220mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*Clearances with double-wall connectors and protected surfaces have not been tested for the Resolute Acclaim.

**A distance of 48" must be maintained between the stove and moveable combustible items such as drying clothes, furniture, firewood, etc.

1When a rear heat shield is installed on a top exit stove, the shield insert must be attached to the shield so the area behind the flue collar on the stove is protected.

2Chimney connector heat shields must extend exactly 28" (710 mm) above the flue collar of the stove. No shielding can be used on the connector above 28" (710 mm). The unshielded chimney connector above the 28" (710 mm) point will be 14" (360 mm) from an unprotected wall or 8" (200 mm) from a protected wall.

3In top exit installations, this clearance requires the use of the rear stove heat shield with the shield insert installed.

12

2000893

Page 12
Image 12