Majestic Appliances 39LDVR Fuel Conversion Instructions, LDVR Series Direct Vent Gas Fireplace

Models: 33LDVR 43LDVR 39LDVR 36LDVR

1 40
Download 40 pages 23.84 Kb
Page 30
Image 30
Fuel Conversion Instructions

LDVR Series Direct Vent Gas Fireplace

Fuel Conversion Instructions

The conversion of this appliance from one gas to another must be carried out by an authorized service provider.

1.

Disconnect power to the unit and shut off the gas sup-

 

ply.

2.

Remove window frame assembly.

3.

Carefully remove the logs & lava rock material.

4.

Remove the screws that are holding the burner hous-

 

ing in place.

5.

Remove the burner housing assembly. Depending on

 

the model of the appliance you may have to loosen

 

the pilot bracket retaining screw/nut to allow the pilot

 

and bracket assembly to tilt and give enough clear-

 

ance to remove the burner housing assembly.

d.Refit the regulator cap.

e.Mount conversion label supplied with conversion screw to valve in a visible position.

10.Reassemble the fireplace in the reverse order, except for the window frame assembly. Leave this off until after the unit has been checked for leaks and the gas supply has been bled.

11.After bleeding the gas line and checking for leaks with a soap solution, replace the window frame assembly. Fire up the unit, check for flame impingement on the logs, adjusting them if necessary. Check the manifold and supply pressures against the appliance specifica- tions.

A

E

6.

Remove the main burner orifice and replace it with the

 

orifice supplied in the conversion kit.

7.

SIT top Convertible Pilot

 

Gently lift off the pilot hood from the pilot. (Do not re-

 

move the spring clip holding the hood in place). Using

 

a 5/32” Allen key, unscrew the exposed orifice. Insert

 

the new orifice supplied in the kit, do not over tighten

 

the orifice. Replace the pilot hood ensuring the index

 

tab aligns with the notch on the hood.

8.

PSE Pilot

 

Using a suitable wrench on the hexagonal body un-

 

screw the pilot hood assembly from the pilot, do

 

not twist the hood itself. Remove the orifice and

B

C

 

OFF

 

P

 

I

O

TO

 

OFF

 

P

 

I

O

TO

F

SIT top Convertible PilotD

FC107/108

replace it with the new orifice supplied in the kit. Refit

the pilot hood assembly. Do not over-tighten the pilot

hood. The hood must return to its original alignment.

Take care not to damage the thermocouple, thermo-

pile or igniter.

9. SIT 820 NOVA Gas Control Valve (Fig. 52)

a. Using a Torx T20 or slotted screwdriver, remove

and save the three pressure regulator mounting

screws (A), pressure regulator tower (B) and

diaphram (C).

b. Ensure the rubber gasket (D) is properly positioned

and install the new HI/LO pressure regulator to the

valve using the new screws (E) supplied with the

kit. Tighten screws securely. (Reference torque - 25

in.LB)

c. Install the enclosed identification label (F) to the

valve body where it can be easily seen.

Honeywell Gas Control Valve (Fig. 53)

The Honeywell valve fitted to this unit is suitable for use with LP or Natural Gas. It is converted to the required gas application by the installation of a color coded “conversion screw”.

a.Using a suitable small screwdriver lift out the central regulator cap from the “HI/LO” knob on the valve.

b.Unscrew the exposed conversion screw.

c.Insert the new color coded conversion screw. Do not over-tighten the screw, it must be finger tight.

Fig. 52 Nova SIT820 Gas Valve.

Regulator Cap

Conversion Screw

 

O

L

Pressure Regulator

 

 

Housing

HV120

Fig. 53 Honeywell Gas Valve.

The procedure for converting from one gas to another is the same regardless of the initial gas used. The only variation is in the orifice sizes and component part numbers. Your authorized service provider will ensure the correct parts are used.

30

10007317

Page 30
Image 30
Majestic Appliances 39LDVR Fuel Conversion Instructions, LDVR Series Direct Vent Gas Fireplace, SIT top Convertible Pilot