Majestic Appliances 43LDVR Gas Line Installation, Remote ON/OFF Switch, Alternate Switch Location

Models: 33LDVR 43LDVR 39LDVR 36LDVR

1 40
Download 40 pages 23.84 Kb
Page 7
Image 7
Gas Line Installation

Gas Line Installation

When purging the gas lines, the front win- dow frame assembly must be removed.

The gas pipeline can be brought in through the rear of the appliance as well as the bottom. Knockouts are provided on the bottom behind the valve to allow for the gas pipe installation and testing of any gas connection. It is most convenient to bring the gas line in from the rear right side of the valve as this allows fan installation or removal without disconnecting the gas line.

The gas line connection can be made with properly tinned 3/8” copper tubing, 3/8” rigid pipe or an ap- proved flex connector. Since some municipalities have additional local codes, it is always best to consult your local authority and the National Fuel Gas Code, ANSI Z223.1/NFPA 54 in the USA or the CSA-B149.1 instal- lation code.

1/2” Gas Supply

1/2” NPT x 1/2” Flare Shut-

off Valve

3/8” Flex Line

(From Valve)

FP297A

Fig. 5 Typical gas supply installation.

Always check for gas leaks with a mild soap and water solution. Do not use an open flame for leak testing.

The gas control is equipped with a captured screw type pressure test point, therefore it is not necessary to pro- vide a 1/8” test point up stream of the control.

When using copper or flex connector use only approved fittings. Always provide a union when using black iron pipe so the gas line can be easily disconnected for burner or fan servicing. See gas specification for pres- sure details and ratings.

The fireplace valve must not be subjected to any test pressures exceeding 1/2 psi. Isolate or disconnect this and any other gas appliance control from the gas line when pressure testing.

LDVR Series Direct Vent Gas Fireplace

Remote ON/OFF Switch

Installation

1.Thread the wiring through the holes on the end panels of the fireplace. Take care not to cut the wire or insulation on metal edges. Route the wire to a conveniently located receptacle box.

2.Attach the wire to the ON/OFF switch and install the switch into the receptacle box.

3.Connect the other ends of the wire to the gas control valve. (Fig. 6)

Remote ON/OFF Switch or Thermostat

or Remote Control

TP

 

TH

Gas

 

Control

TP

Valve

TH

 

 

FP1224

Fig. 6 Remote switch wiring diagram.

Alternate Switch Location

The remote switch can be installed on the front/side of the access door. Simply mount the switch to the bracket provided and screw the bracket to either side of the frame, lining up the screws with the pre-punched holes. (Fig. 7)

FP1024

Fig. 7 Alternate switch location.

Do not wire the remote ON/OFF wall switch for the gas fireplace to the 120 volt power supply.

10007317

7

Page 7
Image 7
Majestic Appliances 43LDVR, 33LDVR, 36LDVR Gas Line Installation, Remote ON/OFF Switch, Alternate Switch Location, 10007317