Majestic Appliances 33LDVR, 36LDVR EB-1Electrical Box, Electronic Gas Control Valve, 10007317

Models: 33LDVR 43LDVR 39LDVR 36LDVR

1 40
Download 40 pages 23.84 Kb
Page 8
Image 8
EB-1 Electrical Box

LDVR Series Direct Vent Gas Fireplace

EB-1 Electrical Box

The fireplace, when installed, must be electrically connected and grounded in accordance with local codes or, in the ab- sence of local codes, with the current CSA C22.1 Canadian Electrical Code.

For USA installations follow local codes and the national electrical code ANSI/ NFPA No. 70.

It is strongly suggested that the wiring of the EB-1 Electrical Junction Box be carried out by a licensed electrician.

Ensure that the power to the supply line has been disconnected before commenc- ing this procedure.

The EB-1 Electrical junction box has been fitted stand- ard on this model to allow for the easy connection of an optional fan kit.

To connect the EB-1 box to the house electrical supply follow the steps below.

1.Unscrew the retaining screw from the EB-1 base plate and remove the EB-1 assembly from the appliance. (Fig. 8)

2.Remove the front cover of the EB-1 box.

3.Remove the plug socket assembly from the EB-1 box.

4.Feed the supply line in through the EB-1 opening in the side of the appliance and then through the back of the EB-1 assembly. (Fig. 8)

5.Connect the black wire of the power supply line to the brass screw (polarized) of the socket assembly.

6.Connect the white wire of the power line to the chrome screw of the socket assembly.

7.Connect the ground wire of the supply line to the green screw of the socket assembly.

8.Refit the socket assembly back into the electrical box and replace the cover plate. Secure the cable with the clamp on the outside of the EB-1 base plate and refit the EB-1 assembly to the unit with the screw removed in step 1.

INSIDE

Electrical Box

 

 

Retaining Screw

������������

 

OUTSIDE

 

BACK

OF

UNIT

FP580

 

 

 

Fig. 8 EB-1 receptacle.

Electronic Gas Control Valve

This appliance may be fitted with a Synetek ignition module.

Installation of the remote on/off starter switch or wall thermostat on electronic ignition units.

1.Thread the wiring through the holes on the side panels of the appliance. Take care not to cut the wire or insulation on metal edges. Route the wire to a conveniently located receptacle box.

2.Attach the wire to the ON/OFF switch and install the switch into the receptacle box.

3.Connect the white wire from the wall switch or wall thermostat to the white wire terminal from the elec- tronic module. Connect the black wire from the wall switch or the red wire from the wall thermostat, to

the red wire terminal from the electronic module.

8

10007317

Page 8
Image 8
Majestic Appliances 33LDVR, 36LDVR EB-1Electrical Box, Electronic Gas Control Valve, LDVR Series Direct Vent Gas Fireplace