3-11
Nº326S Preamplifier Setup Menu

Setup Menu Parameters

Default Possible
Parameter Setting Settings
Mute -20.0dB -10.0dB to -80.0dB
MaxVol 80.0dB 40.0dB to 80.0dB
Trig. 12v,L 12v,L; 5v,P
Sw x.xx x.xx
Mute Determines the amount of master volume level attenuation that
–10.0dB to –80.0dB occurs when mute is activated with the front panel or remote
control mute button. The mute level can be set in 0.1dB increments
between –10.0dB and –80.0dB. The factory-default mute level is
–20.0dB.
MaxVol Determines the maximum master volume level setting in 0.1dB
40.0dB to 80.0dB increments between 40.0dB and 80.0dB. The factory-default maxi-
mum master volume level is 80.0dB.

Trig. Configures the trigger output signal. Selecting the 12v,L setting

12v,L; 5v,P configures the trigger output connector to send a 12V, level
(constant) signal to the connected component whenever the
Nº326S is taken out of standby. This signal is not present when
the Nº326S is placed into standby. Selecting the 5v,P signal
configures the trigger output connector to send a 5V pulse signal,
similar to that of a momentary contact switch, to the
connected component whenever the standby button is pressed.
This signal is only present when the standby button is pressed.
Sw Indicates the current software version operating in the Nº326S,
Non-adjustable allowing for quick comparison between the current software
version and most current software version available. Software
upgrades can be performed with the RS-232 port, allowing software
to be upgraded without disassembling the Nº326S or disconnecting
it from other components.
(continued)