5-3
Nº326S Preamplifier Troubleshooting & Maintenance
“Missing” Input Make sure the Name parameter for the selected input has not
been set to unused.
No Link Controls 1. Make sure the slave chain includes Mark Levinson components
that are compatible with the Nº326S.
2. Examine Link connections to ensure a solid connection
between linked components.
3. Make sure Link connections have been made using Link
communication ports and supplied or constructed Link
communication cables.
4. Make sure constructed Link communication cables have been
twisted 180˚ as shown in the illustration at the bottom of page
2-10 for a straight-through (pin 1-to-pin 1) connection.
5. Examine the slave chain to ensure that connections meet all
of the requirements listed in the table on page 2-11.
6. Make sure Link controls have been enabled on the linked digital
transport(s) linking menu, which allows activation and
deactivation of individual Link controls. Refer to the appropriate
digital transport owner’s manual for additional information.
7. Make sure linked components have been powered on in the
order specified in step 4 (page 2-12). Linked components must
be powered on ONE AT A TIME in this order to ensure proper
functioning of Link controls.
Erratic Behavior 1. Power cycle the Nº326S, waiting at least 10 seconds between
powering the Nº326S off and on.
2. Restore factory-default settings.
If All Else Fails... 1. Power cycle the Nº326S, waiting at least 10 seconds between
powering the Nº326S off and on.
2. Restore factory-default settings.
3. Contact an authorized Mark Levinson dealer.
4. Contact Mark Levinson Customer Service at 781-280-0300 or
www.marklevinson.com.