SWITCH SETTINGS
There are installer selectable switches located on the bottom of the 2802CID base unit. These switches are hidden behind a plastic cover for security. To locate, remove the plastic covers using a sharp pointer or paper clip as shown.
Tone/Pulse Dialing Selector
The 2802CID has the option to out
Message Waiting Selector
The 2802CID can support 90VDC neon or low - voltage LED (FSK compatible) message waiting systems. Simply slide the switch to the desired position that is compatible with your PBX messaging system. Note: the 2802CID is factory preset to the “Neon” setting.
Line Voltage Selectors
The 2802CID is designed to operate behind PBX telephone systems rated between 24 volts and 48 volts. There are line voltage selector switches that must be set according to the PBX system rating that the 2802CID will be installed. There are two (2) switches, the first for Line 1 and the other for Line 2. Each switch has three (3) setting options. They are: “24V/48V/ OFF”. Set the switches by simply sliding to the appropriate setting. The ”OFF” setting is used to turn off the line if a line appearance is not wired to the telephone. Note: the 2802CID is factory set to the “24V” setting.