M A I N T E N A N C E A N D B A S I C S E R V I C E

The MAC 500/E operates under challenging conditions presented by heat, humidity, dust, and touring. It requires reg- ular cleaning and lubrication to keep performing at its peak. The maintenance schedule will depend heavily on the application and should be discussed with your Martin technician. This section describes basic maintenance. Refer any service procedure not described here to a qualified technician.

I M P O R T A N T !

Excessive dust, grease, and smoke fluid buildup degrades performance and causes overheating and damage to the fixture that is not covered by the war- ranty. If you do not feel completely competent to perform the service, consult qualified service personnel.

A c c e s s i n g p a r t s

W A R N I N G !

Disconnect the fixture from AC power before removing any cover.

O p e n i n g t h e h e a d

1. Disconnect the fixture from AC power and allow it to cool.

2.Remove the top shell (look at the label on the back of the head to see which side is the top) by turning the

2 fasteners 1/4 turn counterclockwise with a large screwdriver, and lift off the shell.

O p e n i n g t h e b a s e

To access base components, remove the 2 cover plates from the top

of the base. Each plate is fastened with 4 screws. 'R￿QRW￿UHPRYH￿WKH￿FXUYHG￿SODWHV￿IURP￿WKH￿VLGH￿RI￿WKH￿EDVH￿

R e m o v i n g t h e p r i n t e d c i r c u i t b o a r d

1.Disconnect the fixture from AC power. Remove the cover plate from the front of the fixture.

2.Unplug the white plastic wire connectors from the top of the printed circuit board. To unplug a connector, hold the plastic connector - never pull the wires - and pull it straight off the pins.

3.Grasp the black pins on either end of the circuit board and gently pull it out. You may have to guide some wires past the motor housing. Be careful not to knock the copper heat sinks.

4.To replace the circuit board, gently put it back in the base. You may have to guide some wires past the motor housing. Push the black pins down to lock the board in place.

5.Reconnect the wire connectors. The connectors are labelled on the side that faces up, away from the ICs. The connection order is:

PL551: TILT

PL531: PAN

PL521: DIM

PL511: COL2

PL501: COL1

PL441: ROGO

PL431: GOBO1

PL421: IRIS

PL411: FOCUS

PL401: ROPRI

PL701: PRISM

PL301: GOBO2

PL304: 2-pin fan

PL303: FAN

PL203: OPTO2

PL202: OPTO1

PL201: display

6.Replace the cover before applying power.

Maintenance and Basic Service