safety wire attachment point
arrow points to front (neutral pan)
5.Working from a stable platform, hang the fixture on the truss. The front of the fixture is indicated by the arrow on the base.
6.Install a safety wire that can bear at least 10 times the weight of the fixture. The attachment point is designed to fit a caribiner clamp. Never use the carrying handles for secondary attach- ment.
7.Tighten the rigging clamps securely to the structure.
8.Verify that there are no combustible materials or surfaces to be illuminated within 1 meter of the fixture, and that there are no flammable materials nearby.
I M P O R T A N T !
When rigging the fixture within 1 meter of other fixtures, avoid illuminating
one fixture with another. The intense light can melt plastic parts.
C o n n e c t i n g t h e s e r i a l l i n k
T i p s f o r b u i l d i n g a s e r i a l l i n k
1.Use shielded
2.Never use a “Y” connector to split the link. To split the serial link into branches use a splitter such as the Martin
3.Do not overload the link. Up to 32 devices may be connected on a serial link.
4.Terminate the link by installing a termination plug in the output socket of the last fixture on the link. The termination plug, which is simply a male XLR connector with a 120 ohm, 0.25 watt resistor soldered between pins 2 and 3, “soaks up” the control signal so it does not reflect back down the link and cause interference. If a splitter is used, terminate each branch of the link.
C o n n e c t i n g f i x t u r e s
The MAC 500/E has locking
to signal
Cable
Connections
Male Female
11
22
33
P/N 11820006
Cable
Connections
Male Female
11
22
33
4
5
P/N 11820002
Cable
Connections
Male Female
11
22
33
P/N 11820003
Straight
Cable
Connections
Male Female
11
22
33
P/N 11820005
Connections
Male Female
11
22
33
4
5
P/N 11820004
Setup | 7 |