M A C 5 0 0 E w i t h e l e c t r o n i c b a l l a s t

Electronic ballast models that come factory set for 100 V or 120 V have a 10 A main fuse, which is located near the power switch. Units set at 210 V and above have a 6.3 A main fuse. Use a 6.3 A fuse when the WUDQVIRUPHU is set at

200, 210, 220, 230, or 240 V. Use a 10 A time-delay fuse when it is set at 100, 110, or 120 V.

No rewiring of the electronic EDOODVW is necessary; it works at any voltage between 100 and 250 volts, and at any fre- quency between 50 and 60 Hz. The WUDQVIRUPHU must be tapped for the local supply voltage as shown below.

 

black

 

 

 

 

 

black

 

 

 

 

 

black

 

 

 

 

6

7

8

 

9

 

6

7

8

9

 

 

6

7

8

9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

 

 

 

 

5

 

 

 

brown

 

5

 

 

 

 

 

 

 

 

 

 

 

 

red

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

blue

4

100 V

brown

 

4

110 V

 

 

4

120 V

 

 

 

 

 

red

 

 

 

 

 

 

 

 

 

 

 

brown

3

 

 

 

 

blue

3

 

 

 

 

blue

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

red

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

blue

1

 

 

 

blue

 

1

 

 

 

blue

 

1

 

 

 

blue

 

 

 

blue

 

 

 

 

blue

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

brown

 

 

 

 

brown

 

 

 

 

brown

 

 

 

red

 

 

 

 

 

red

 

 

 

 

red

 

 

 

 

7

8

9

 

 

7

8

9

 

 

 

7

8

9

 

6

 

 

 

black

 

6

 

 

 

black

 

6

 

 

 

black

5

 

 

 

 

5

 

 

 

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

210 V

 

 

 

4

220 V

 

 

 

4

230 V

 

 

3

 

 

 

 

 

3

 

 

 

 

 

3

 

 

 

blue

1

 

 

 

blue

 

1

 

 

 

blue

 

1

 

 

 

blue

 

 

 

blue

 

 

 

 

blue

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MAC 500 E Transformer Settings

 

 

U p d a t i n g s o f t w a r e

 

 

 

 

 

 

 

 

 

 

 

brown red

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

7

8

9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

black

 

 

 

 

5

 

200 V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

blue

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

blue

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

brown red

7 8 9

 

black

 

6

 

 

 

 

 

 

5

 

 

 

 

240 V

 

 

 

 

 

 

4

 

 

 

blue

 

 

3

 

 

 

 

 

 

1

 

blue

 

 

 

 

 

 

 

The latest software for the MAC 500/E is available from your Martin dealer and the Martin Professional web site. Please read the update notes bundled with the software. Update software is uploaded to the MAC 500/E using a Martin uploader such as the MBPP1, or MP-2.

N o r m a l u p l o a d

Connect the uploader to the fixture just like a controller. Under normal conditions, software can be installed from a remote location - there is no need to set the MAC 500/E to boot mode. Please refer to the uploader manual for further instructions.

B o o t m o d e u p l o a d

If the data is corrupted during transmission, a check-sum error (CSER) will occur and after 15 seconds the fixture will automatically switch to boot mode (UPLd) and be ready for a boot-mode upload as described below and in the uploader manual.

If a software upload to the MAC 500/E is interrupted, the fixture must be powered off for at least 10 seconds before a new upload can be attempted. When powered on, a check-sum error will occur and it will automatically go into boot mode, ready for a second upload attempt. Select boot mode upload on the uploader.