![INSTRUCTIONS FOR USE](/images/new-backgrounds/88747/8874717x1.webp)
Instruction Manual there is an envelope, which contains a spare choke and an adhesive label that indicates the type of gas that the burner should use.
INSTRUCTIONS FOR USE
SWITCHING ON
•Set the control knob (2) to position “0”.
•Turn on the disconnecting switch on the electric switchboard.
•If the unit is operated manually turn the control knob to .The burner starts up, the combustion chamber heats up and then the fan starts.
•If the unit operates automatically set the room thermostat to the desired level and turn the control knob (2) to : the heater will now start and stop automatically.
•If the heater doesn’t start after you have completed the above operations consult the Troubleshooting section of this manual.
TURNING OFF
WarningNever stop the heater by simply turning off the disconnecting switch on the electric switchboard. The electrical supply must only be disconnected when the fan has come to a complete stop.
In manual operation turn control knob (2) to “0” or turn off control in automatic operation.
The burner stops while the fan turns itself on and off until the combustion chamber has completely cooled down.
VENTILATION
When the control knob is turned to the symbol the heater operates in continuous fan mode.
MAINTENANCE
Warning: Qualified personnel must carry out the following operations.
Warning: Before carrying out any maintenance operation the heater must be disconnected from the mains. There- fore:
•Stop the machine as instructed above
•Turn off the disconnecting switch on the electric switchboard.
•Wait until the heater has cooled down.
CLEANING THE HEAT EXCHANGER AND THE COM- BUSTION CHAMBER
For the heater to operate efficiently the heat exchanger and combustion chamber must be cleaned after a period of prolon- ged use and more frequently if too much soot builds up. Soot builds up when there is not enough chimney draft, when the fuel is of very poor quality, when the burner is regulated incorrectly or when the heater is switched on and off too frequently. If the heater starts vibrating when it is turned on there is probably too much soot.
To get at the internal parts of the heat exchanger (1), remove the burner (2), take off the upper back panel (3), the exchanger inspection panels (4) and the baffle plates (5). Clean out soot or extraneous material with a vacuum cleaner or tube cleaner.
CLEANING THE FAN
WARMLUFTERHITZER
9
DE
CLEANING THE BURNER
For the heater to work efficiently the burner must be serviced re- gularly by an Authorized Service Technician. All cleaning, servi- cing and regulation operations must be carried out as indicated in the Burner Instruction Manual.
5
1
4
2
3
6 | Fig. 5 |
TRANSPORTING AND MOVING THE HEATER
To move or transport the heater, place it on a raised base and lift with by a forklift truck.
Warning: Before moving the unit:
•Turn it off as indicated above.
•Disconnect electricity by pulling out the plug.
•Wait until the heater cools down
•Never try to lift the heater manually. Doing so could result in physical injury.
Remove any dirt or extraneous material from the mesh of the aspiration grill (6) and if necessary clean the propeller with an