ITEM | NAME | DESCRIPTION |
1. | THRESHHOLD PLATE | Component that bridges the entry way, through |
|
| the Lift, into the vehicle. Detects if that portion of |
|
| Lift is occupied during "UP/DOWN" operation |
|
| between vehicle floor and the ground. |
|
|
|
2. | OUTBOARD ROLLSTOP | Barrier to prevent the Wheelchair from rolling off |
|
| of the Platform. Also provides entry/exit ramp for |
|
| Platform on the ground. |
|
|
|
3. | SEAT BELT | Belt that acts as an additional barrier to keep the |
|
| Wheelchair or ambulatory occupant on the |
|
| Platform. Belt must be fastened for Lift to |
|
| operate. |
4. | PLATFORM | Contains the Wheelchair and Occupant during |
|
| "UP/DOWN" operation between vehicle floor and |
|
| the ground. |
5. | HANDRAILS | (Left/Right) Provides a hand hold for the Lift |
|
| Occupant. |
6. | INBOARD ROLLSTOP | Barrier to prevent the Wheelchair from rolling off |
|
| inboard side of Platform. Also, provides bridge |
|
| between Platform and Threshhold. |
7. | ELECTRICAL ACTUATOR | Raises/lowers Inboard Rollstop. |
|
|
|
ITEM | NAME | DESCRIPTION |
8. | HYDRAULIC CYLINDER | (Left/Right) Telescoping steel tube and rod, |
|
| pressurized by hydraulic fluid, that folds and |
|
| unfolds the Lift and moves the Lift up and down. |
|
|
|
9. | HYDRAULIC POWER UNIT | Contains motorized hydraulic pump, manually |
| (COVER IS SHOWN) | operated backup pump, fluid lines, and controls |
|
| to operate the hydraulic cylinders. |
|
|
|
10. | LIFT CONTROLLER | Electronic device that controls and monitors Lift |
|
| operation and the interlock connection with the |
|
| vehicle. |
|
|
|
11. | BASE | Structure that secures Lift to the vehicle floor. |
|
|
|
12. | THRESHHOLD WARNING | Flashing red light indicates Threshhold is |
| BEACON | occupied by a person or object during |
|
| "UP/DOWN" operation between vehicle floor |
|
| and the ground. |
|
|
|
13. | THRESHHOLD WARNING | Audible alarm sounds when Threshhold is |
| ALARM | occupied by a person or object during |
|
| "UP/DOWN" operation between vehicle floor |
|
| and the ground. |
|
|
|
TABLE