Maxtor 16Channel Stand Alone DVR manual Alarm Setup, Event Popup Setup, Interval Setup

Models: 16Channel Stand Alone DVR

1 59
Download 59 pages 60.39 Kb
Page 26
Image 26

CHAP. 5 Set Up

4) INTERVAL SETUP

Set the switching time interval for SEQ or PIP function.(1 sec. ~ 99 sec.)

INTERVAL SETUP

 

 

 

SWICHING INTERVAL

 

FULL SCREEN

01 SEC

PIP SCREEN

01 SEC

 

 

(1)FULL SCREEN : set the sequencing switch time interval EVENT RECORD

in live full screen.

EVENT UPDATE TIME

01 SEC

 

 

(2)PIP SCREEN : set the sequencing switch time interval of PIP window.

SELECT ▲▼◀▶, CHANGE VALUE : - +

(3)EVENT UPDATE TIME : Set the minimum time interval of event to be listed in EVENT LIST.

If EVENT UPDATE TIME is set at 20 sec, only following event happened

20 sec or more than 20 sec later previous event shall be listed in EVENT LIST.

5) ALARM SETUP

Set type of alarm sensors connected to DVR unit. N.O represents Normal Open type and N.C Normal Close type.

(1)ALARM INPUT : Select type of alarm sensor connected to DVR unit (N.O or N.C). Use direction button and [-] [+] button to set.

DISABLE represents not to use alarm sensor connected to DVR.

(2)DURATION : Set the duration of alarm when an alarm is activated. (0 sec. ~ 300 sec.)

6)EVENT POPUP SETUP

When event is activated, the full image will pop up as user set.

(1)CHANNEL : Choose a channel

(2)POPUP ON/OFF : Set a popup function at ON/OFF

(3)EVENT : Set event mode which ‘popup’ function is applied to.

*A : ALARM event. M : MOTION event.

(4)DURATION : Set the duration how long the popup Image is shown.(0 sec. ~ 60 sec.)

If more than 2 channels pop up at the same time, the first channel out of them will be shown.

(For e.g. Ch1 and CH3 pop up at the same time, CH1 will be shown)

 

ALARM SETUP

 

 

 

 

CHANNEL

 

 

CH1

ALARM INPUT

 

 

N.O

DURATION

 

 

005

 

 

 

 

N.O

NORMAL OPEN

N.C

NORMAL CLOSE

___

DISABLE

 

 

 

 

SELECT : ▲▼, CHANGE VALUE : - +

EVENT POPUP SETUP

 

 

 

CHANNEL

CH01

POPUP ON / OFF

ON

EVENT

AM

DURATION

0 3

 

 

 

 

SELECT : ▲▼, CHANGE VALUE : - +

25

Page 26
Image 26
Maxtor 16Channel Stand Alone DVR manual Alarm Setup, Event Popup Setup, Interval Setup