Maxtor 54098U8, 51024U2, 52049U4, 51536U3 SubsystemConfiguration, Jumper Location / Configuration

Models: 51536U3 53073U6 52049U4 54098U8 51024U2

1 62
Download 62 pages 6.76 Kb
Page 14
Image 14
SubsystemConfiguration

PRODUCT DESCRIPTION

SubsystemConfiguration

Dual Drive Support

Two drives may be accessed via a common interface cable, using the same range of I/O addresses. The drives are jumpered as device 0 or 1 (Master/Slave), and are selected by the drive select bit in the

Device/Head register of the task file.

All Task File registers are written in parallel to both drives. The interface processor on each drive decides whether a command written to it should be executed; this depends on the type of command and which drive is selected. Only the drive selected executes the command and activates the data bus in response to host I/O reads; the drive not selected remains inactive.

A master/slave relationship exists between the two drives: device 0 is the master and device 1 the slave. When J50 is closed (factory default, figure 2-1), the drive assumes the role of master; when open, the drive acts as a slave. In single drive configurations, J50 must be closed.

Cable Select Option

CSEL (cable select) is an optional feature per ANSI ATA specification. Drives configured in a multiple drive system are identified by CSEL’s value:

If CSEL is grounded, then the drive address is 0.

If CSEL is open, then the drive address is 1.

Jumper Location / Configuration

Darkened jumper pins indicate factory-installed (default) shunts.

+12 VDC

+12

V return

+5

V return

EIDE Interface Connector

+5 VDC

J1 – pin 1

 

J50 - Master/Slave

Power Connector

J2

 

J48 - Cable Select

 

J46 - Cylinder Limitation

 

J44 - Factory Reserved

 

J42 - Factory Reserved

 

JUMPER CONFIGURATION

J50

J48

J46

J44

J42

 

 

 

 

 

 

Master/Slave

 

 

 

 

 

Only drive in single drive system*

C

 

 

 

 

Master drive in dual drive system*

C

 

 

 

 

Slave drive in dual drive system

O

 

 

 

 

 

 

 

 

 

 

Cable Select

 

 

 

 

 

Disabled*

 

O

 

 

 

Enabled

 

C

 

 

 

 

 

 

 

 

 

Cylinder Limitation

 

 

 

 

 

Disabled*

 

 

O

 

 

Enabled

 

 

C

 

 

 

 

 

 

 

 

Factory Reserved

 

 

 

O

 

 

 

 

 

 

 

Factory Reserved

 

 

 

 

O

 

 

 

 

 

 

Key * = Default C = Closed (jumper installed) O = Open (no jumper installed)

 

 

 

 

 

 

Figure 2-1

PCBA Jumper Location and Configuration

CylinderLimitationJumperDescription

On some older BIOS', primarily those that auto-configure the disk drive, a hang may occur. The Cylinder Limitation jumper reduces the capacity in the Identify Drive allowing large capacity drives to work with older BIOS'. The capacity reported when J46 is closed will be as follows: drives less than or equal to 32GB will report 2.1GB. Drives greater than 32GB will report 32GB.

2 – 5

Page 14
Image 14
Maxtor 54098U8, 51024U2 SubsystemConfiguration, Jumper Location / Configuration, CylinderLimitationJumperDescription