AT INTERFACE DESCRIPTION

PIO Timing

TIMING PARAMETERS

MODE 0

MODE 1

MODE 2

MODE 3

MODE 4

 

 

 

 

 

 

 

t0

Cycle Time (min)

600 ns

383 ns

240 ns

180 ns

120 ns

t1

Address valid to DIOR-/DIOW- setup (min)

70

ns

50

ns

30

ns

30

ns

25

ns

t2

DIOR-/DIOW- 16-bit (min)

165 ns

125 ns

100 ns

80

ns

70

ns

t2i

DIOR-/DIOW- recovery time (min)

 

 

 

 

 

 

70

ns

25

ns

t3

DIOW- data setup (min)

60

ns

45

ns

30

ns

30

ns

20

ns

t4

DIOW- data hold (min)

30

ns

20

ns

15

ns

10

ns

10

ns

t5

DIOR- data setup (min)

50

ns

35

ns

20

ns

20

ns

20

ns

t6

DIOW- data hold (min)

5 ns

5 ns

5 ns

5 ns

5 ns

t6Z

DIOR- data tristate (max)

30

ns

30

ns

30

ns

30

ns

30

ns

t9

DIOR-/DIOW- to address valid hold (min)

20

ns

15

ns

10

ns

10

ns

10

ns

tRd

Read Data Valid to IORDY active (min)

 

0

 

0

0

 

 

0

0

 

tA

IORDY Setup Time

35

ns

35

ns

35

ns

35

ns

35

ns

tB

IORDY Pulse Width (max)

1250 ns

1250 ns

1250 ns

1250 ns

1250 ns

Figure 5 - 2

PIO Data Transfer To/From Device

5 – 3

Page 27
Image 27