INTERFACE COMMANDS

Mode Set/Check Commands

Set Features Mode

Enables or disables features supported by the drive. When the drive receives this command it:

1.Sets BSY,

2.Checks the contents of the Features register,

3.Clears BSY and

4.Generates an interrupt.

If the value of the register is not a feature supported by the drive, the command is aborted. The acceptable values in the Features register are defined as follows:

VALUE

DESCRIPTION

0 2 h

Enabled Write Cache

03h

Set Transfer Mode based on value in Sector Count register

05h

Enable Advanced Power Management

42h

Enable Automatic Acoustic Management. The sector count register contains the

 

Automatic Acoustic Management level.

 

S E C T O R

L EV E L

 

F F h

Maxtor specific

 

FEh

Maximum performance

 

81h - FDh

Intermediate acoustic management levels

 

80h

Minimum acoustic emanation level

 

00h-7Fh

reserved

44h

Length of data appended on Read Long/Write Long commands specified in the

 

Identify Device information

55h

Disable Read Look-ahead feature

66h

Disable reverting to Power-on defaults

82h

Disable Write Cache

85h

Disable Advanced Power Management

AAh

Enable Read Look-ahead feature

BBh

4 bytes of Maxtor specific data appended on Read Long/Write Long commands

C2h

Disable Automatic Acoustic Management

C C h

Enable reverting to Power-on defaults

7 – 6

Page 46
Image 46
Maxtor 96147H8, 93073H4, 91536H2, 94610H6, 92305H3 specifications Mode Set/Check Commands, Value Description, Ev E L