INSTALLATION AND CONNECTION | |
|
|
9.4. Connecting External Device with Serial Port
9.4.1. Connecting Text Input Device (ATM / POS / Access Control)
In addition to images, the ELX16- 240 can record text data received from POS/ATM through the COM1/RS232 serial port.
Connect to COM1/RS232 (9pin D- Sub) of ELX16
9.4.2. Configuring Serial Setup (COM1) at OSD menu
(1)Set the “System ” in OSD menus, and move to “Serial Setup ” menu.
(2)Select COM1 in “Serial Setup ”, set Device as “Text ”.
(3)Set Baud Rate/Parity/Stop bit/Data bit with referring to manual of the connected extern al device.
Rugged CCTV | Error! Unknown document property name | 35 |