Microwave Leakage Testing

!WARNING

To avoid risk of electrical shock, personal injury, or death, disconnect power to oven and discharge capacitor before servicing, unless testing requires power.

!WARNING

Check for radiation leakage after servicing. Should the leakage be more than 4 mW/cm2 inform Maytag immediately. After repairing or replacing any radiation safety device, keep a written record for future reference, as required by D.H.H.S. and HEW regulations. This requirement must be strictly observed. In addition, the leakage reading must be recorded on the service repair ticket while in the customer’s home.

Equipment

Electromagnetic radiation monitor

600 cc glass beaker or plastic power bowl

Procedure for Measuring Radiation Leakage

Note before measuring:

Do not exceed meter full scale deflection. Leak monitor should initially be set to the highest scale.

To prevent false readings the test probe should be held by the grip portion of the handle only.

The scan speed is equal to one inch per antenna revolution or one inch per second if antenna speed is unknown.

Areas to be checked are all door seal areas and any venting parts.

Leakage with the outer panel removed ...4mW/cm2 or less.

Leakage for fully assembled oven with door normally closed ...4 mW/cm2 or less.

Leakage for a fully assembly oven (before the latch switch (primary) is interrupted) while pulling the door

... 4 mW/cm2 or less.

1.Pour 275 cc ±15 cc (9 oz ±1/2 oz) of 20°C ± 5°C (68°F ± 9°F) water in a beaker which is graduated to 600 cc and place the beaker in the center of oven.

2.Set the radiation monitor to 2450 MHz and use it following the manufacturer’s recommended test procedure to assure correct results.

3.While measuring the leakage, always use the two inch (5 cm) spacer supplied with the probe.

4.Press the start pad or turn on the timer and with the magnetron oscillating, measure the leakage by holding the probe perpendicular to the surface being measured.

Measurement with the Outer Panel Removed

!WARNING

Avoid contacting any high voltage components.

Whenever you replace the magnetron, measure for radiation leakage before the outer panel is installed and after all necessary components are replaced or adjusted. Special care should be taken in measuring around the magnetron.

Measurement with a Fully Assembled Oven

After all components including the outer panel are fully assembled, measure for radiation leakage around the door periphery, the door viewing window, the exhaust opening, and air inlet openings.

Record Keeping and Notification After Measurement

1.After any adjustment or repair to a microwave oven, a leakage reading must be taken. Record this leakage reading on the repair ticket even if it is zero.

2.A copy of the repair ticket and the microwave leakage reading should be kept by the repair facility.

18

16026795

©2006 Maytag Services

Page 18
Image 18
Maytag 1800 W - 2005 manual Microwave Leakage Testing

1800 W - 2005 specifications

The Maytag 1800 W, launched in 2005, marked a significant evolution in household appliance technology, combining functionality with durability and aesthetic appeal. Known for its robust design, this model quickly became a favorite among homeowners, delivering a reliable performance that matched the brand's longstanding reputation for quality.

One of the standout features of the Maytag 1800 W is its powerful 1800-watt heating element, which ensures that water reaches its optimal temperature quickly and efficiently. This capability not only saves time but also enhances the effectiveness of various washing programs. The high wattage ensures that even stubborn stains are addressed, making this model a versatile choice for all types of laundry.

The Maytag 1800 W is equipped with an advanced control system that offers a user-friendly interface. A digital display shows the selected settings clearly, allowing users to adjust wash cycles, water temperature, and spin speed with ease. The interface was designed with simplicity in mind, catering to a wide range of users from tech-savvy individuals to those less familiar with modern appliances.

In terms of technologies, the 1800 W incorporates Maytag's innovative PowerWash system. This feature enhances cleaning effectiveness through a combination of increased agitation and optimized wash motions. It enables the washer to tackle tough stains more efficiently, ensuring that clothes come out spotless. Additionally, this model includes a variety of wash settings tailored for different fabric types, including delicate, heavy-duty, and quick wash options, promoting care for a wide array of garments.

Energy efficiency is another hallmark of the Maytag 1800 W. Designed to consume less water and electricity while maintaining robust cleaning performance, this appliance appealed to environmentally conscious consumers looking to reduce their ecological footprint. The integrated energy-saving features allow users to wash large loads without excessive resource use.

The build quality of the Maytag 1800 W is noteworthy as well, constructed with durable materials that ensure longevity and reliability. This model also boasts a sound-dampening system that minimizes operational noise, allowing it to run discreetly during laundry cycles.

In summary, the Maytag 1800 W, launched in 2005, combines powerful cleaning technology, user-friendly controls, energy efficiency, and durability into one compelling package. Its thoughtful design and features made it a responsible choice for modern households, solidifying Maytag’s legacy as a leader in appliance manufacturing.