Maytag 1800 W - 2005 manual Troubleshooting Procedures Electronic Models

Models: 1800 W - 2005

1 33
Download 33 pages 21.52 Kb
Page 16
Image 16
Manual background

Troubleshooting Procedures (Electronic Models)

Trouble 5: No microwave oscillation even when oven light and fan motor operate.

No microwave oscillation.

Disconnect wire leads from relay RY2 and verify continuity of the relay.

No

Continuity

Manual background Continuity

Failed controller.

Replace controller.

Check high

Abnormal

Failed high

Replace high

voltage

 

voltage

voltage

transformer.

 

transformer.

transformer.

 

Normal

 

 

Check high voltage capacitor.

Check high voltage diode.

Abnormal

Normal

Abnormal

Failed high

voltage capacitor.

Failed high

voltage diode.

Replace high voltage capacitor.

Replace high voltage diode.

Normal

Manual background Check magnetron.

Abnormal

Failed magnetron.

Replace magnetron.

Operates at

full power

when

programmed

for lower power.

Disconnect wire leads from relay RY2 and verify continuity of the relay.

Abnormal

Failed controller.

Replace controller.

16

16026795

©2006 Maytag Services

Page 16
Image 16