Service and Disassembly Procedures
!WARNING
To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit and discharge capacitor through a 10,000 ohm resistor before attempting to service, unless test procedures require power to be connected. Ensure all ground wires are connected before certifying unit as repaired and/or operational.
Replacement
1.Examine the Air Water Inlet Seal for damage.
2.Align Air Water Inlet tabs with notches in Tub, and rotate counterclockwise into position.
3.Replace Air Water Inlet Cover inside Tub.
Tub Wheels
To remove, unlatch rear Rack Stop. Slide track out of Dishwasher. Remove tub wheel shaft with Torx™ driver.
NOTE: Tub wheel shaft contains a small steel washer.
Turbidity Sensor
The Turbidity Sensor is located on the bottom and to the left of the Pump Module Assembly. The sensor measures soil level in the water. Turbidity is determined by a beam of infrared light directed from one probe and read by the other. This information is interpreted as water soil level.
Removal
1.Disconnect power to the machine.
2.Remove Front Support and Toe panel. (See paragraph Front Support and Toe Panel removal).
3.Remove the 2 Torx™ screws securing the sensor to the tub bottom.
Upper Rack Removal
To remove Upper Rack, remove Rack Stops. Unlatch stop by moving as shown in direction of arrow toward center of Tub.
4.Pull sensor straight out.
NOTE: When installing sensor, examine the "O" ring seal and replace if necessary. The sensor has alignment ribs to aid in installation.
©2004 Maytag Appliances Company | 16022783 | Rev. 0 | 42 |