©2004
B | From | Isolated Redeposit/ | From |
|
| Water & Detergent | ||
Page 1 | Page 1 | A | ||||||
|
| Original Soil Issues | ||||||
|
| Issues | ||||||
|
|
|
|
|
| |||
|
|
|
|
|
|
|
Wash/Drain
Pump & Valve Issues
Maytag
| Are items nested |
No | together, touching No |
No
Is the incoming water
Yes Increase
| No |
Is the fill volume | Is the water pressure |
Is the redep | other items, or |
Are any of the spray
temperature (at sink)
water
within tolerance? | within tolerance? |
everywhere? | blocking the spray | |
| ||
| path? | |
Yes |
| Yes |
| ||
|
|
|
nozzles clogged?
Yes
temp to
< 120F?
120F
No
Yes |
Yes |
| No |
|
| |
3 Rack - Top surface of | Correct | Is the float |
limiting the |
Rearrange | Be sure and |
|
|
remove |
| Unclog | |
load to |
| ||
large soils, |
| ||
eliminate |
| spray | |
seeds, & |
| ||
problem |
| nozzles | |
hard objects |
| ||
|
|
| |
| from load? |
|
|
| Yes | Change | |
Have you changed | Back | ||
| |||
detergent recently? |
| and try | |
|
| again | |
No |
|
|
discharge housing | water | fill? Repair | |||
2 Rack - 1/4" below top | pressure | or replace float | |||
surface of DH |
|
|
|
|
|
|
|
| No |
|
|
|
|
|
| ||
|
|
|
|
|
|
Heavy/Random
Redeposit Issues
Yes
Remove filter guard &
Did the detergent | No If the dispenser did | ||
completely dissolve? |
|
| not open repair |
|
|
| or replace |
Level | No | Ye | Replace | |
|
|
| ||
Is the unit level? |
| water | ||
unit |
| |||
|
|
| valve | |
|
|
|
|
inspect filter mesh. Is
Replace
it torn?
filter
Troubleshooting Flow Chart
No
Yes
Yes |
| No |
No | Is there something |
|
blocking the |
| |
| Yes | |
| dispenser door? | |
|
|
No
Is the carry over volume correct?
Yes | Unclog | |
Is the drain pump | drain | |
clogged? | ||
pump | ||
|
Appliances Company 16022783 Rev. 0
Is the sample port
Clear
sample
clogged?
port
No |
|
|
Is the filter flapper | No | Install |
| ||
| filter | |
present? |
| |
| flapper | |
|
| |
Yes |
|
|
Are all 4 flapper ears |
| Insert |
| No | Replace | Remove | |
Is the heater | obstruction | |||
| ||||
| heater or |
| ||
working? |
|
| ||
| thermostat |
| ||
|
|
| ||
Yes |
|
|
| |
Are you using | No | Refer to |
| |
|
| |||
automatic D/W |
|
| ||
| U & C |
| ||
detergent? |
|
| ||
|
|
| ||
Yes |
|
|
|
Yes
No |
| |
No | Level | |
Is the unit level? | ||
unit | ||
| ||
Yes |
| |
Yes |
| |
Is the drain outlet | Replace | |
check valve stuck | ||
valve | ||
open? | ||
|
24
| No | |
inserted into the drain |
| flapper |
| ||
port opening? |
| ears |
Determine |
|
|
| Refer to U & C for |
water |
|
|
| R/A & Detergent |
|
|
| ||
hardness? |
|
|
| recommendations |
No
Complete
Yes