Diagnostic Codes
The Diagnostic Codes are identified when the severity level of the abnormality detected is higher and service may be required.
When a problem with the dryer is detected a Diagnostic Code is assigned, and can be displayed. The Control Board will not log multiple same codes per cycle; however, it will log as many Diagnostics as possible for the machine to continue running.
Accessing Diagnostic Codes with 13 Key Membrane Press Air Fluff and Time (^) to enter Service Mode. Press the Wrinkle Release key to access the Diagnostic Codes. Scroll through the Diagnostic Codes by pressing the Temperature (^) key. The first time the key is pressed the newest code will be displayed. Each additional key press shows the next code. Once all the codes have been displayed a “d” is displayed and the process repeats. If there are no Diagnostic Codes available, “00” will be displayed for the Diagnostic Code.
Accessing Diagnostic Codes with 15 Key Membrane Press Air Fluff and Time (+) to enter Service Mode. Press the Wrinkle Release key to access the Diagnostic Codes. Scroll through the Diagnostic Codes by pressing the Temperature (^). The first time the key is pressed the newest code will be displayed. Each additional key press shows the next code. Once all the codes have been displayed a “d” is displayed and the process repeats. If there are no Diagnostic Codes available, “00” will be displayed for the Diagnostic Code.
There will be no multiple occurrences of either a diagnostic code or help code generated in the same cycle reported on the list. But if the same code occurs in repeated cycles, it will be registered.
Clearing Diagnostic Codes
To clear the diagnostic code list press
Air Fluff and Wrinkle Release - 13 Key or
Air Fluff and Wrinkle Release - 15 Key for 3 seconds while in diagnostic mode.
Diagnostic Codes
|
| Code | Description | Trigger | Action Taken | |
|
| 1 | Dryer Thermistor | The | Check for: | |
|
|
| Short Sensed | thermistor | - | Clogged lint |
|
|
|
| resistance is |
| screen. |
|
|
|
| very low, | - | Restricted |
|
|
|
| with a |
| vent system. |
|
|
|
| temperature | Failed thermistor. | |
|
|
|
| > 175 |
|
|
|
|
|
| degrees. |
|
|
1602311016023110
| Code | Description | Trigger | Action Taken | |
2 | Thermistor Open | The | Check for: | ||
|
| Sensed | thermistor | - | Low ambient |
|
|
| resistance is |
| temperature in |
|
|
| very high |
| room (Below |
|
|
|
| - | 50oF/10oC). |
|
|
|
| Outside vent | |
|
|
|
|
| damper is stuck |
|
|
|
|
| open in |
|
|
|
|
| wintertime. |
|
|
|
| Loose or open wire | |
|
|
|
|
| terminals |
3 | Door Circuit | Invalid state | Check for: | ||
|
| Failure | for more | - Loose or open wire | |
|
|
| than 256 | terminals in Door | |
|
|
| milliseconds | Sense circuit. | |
4 | Possible motor | If either | Check for: | ||
|
| transistor error | motor | - | Loose |
|
|
| transistor is |
| connections in |
|
|
| seen open or |
| motor circuit. |
|
|
| shorted | - | Run System |
|
|
| during |
| Check Mode |
|
|
| startup |
| and check the |
|
|
|
|
| motor relay |
|
|
|
| - | function. |
|
|
|
| If relay | |
|
|
|
|
| functions, |
|
|
|
|
| disregard the |
|
|
|
|
| diagnostic |
|
|
|
|
| code. |
|
|
|
| If relay does not | |
|
|
|
| function, replace | |
|
|
|
| machine control | |
|
|
|
|
| board. |
5 | Not Used |
|
|
| |
6 | Non Volatile | Problem |
| Disregard | |
|
| Memory | Detected |
|
|
|
|
| with integrity |
|
|
|
|
| of |
|
|
|
|
| parameters |
|
|
|
|
| stored in |
|
|
|
|
| EEPROM |
|
|
|
|
| memory. |
|
|
8 | Stuck Key | A key is | Run membrane pad | ||
|
|
| sensed to be | check and replace | |
|
|
| pressed | console w/membrane | |
|
|
| more than | pad if necessary. | |
|
|
| 75 seconds, |
|
|
|
|
| the key shall |
|
|
|
|
| be assumed |
|
|
|
|
| to be stuck. |
|
|