General, Connector and Cable Information
General Information | Connector and Cable Information |
1. The C220 uses Vacuum Tubes for amplifying the audio |
signal. The C220 is designed to have only qualified Ser- |
vice Personnel perform any part(s) replacement includ- |
ing all the vacuum tubes. |
2. For additional connection information, refer to the |
owner’s manual(s) for any component(s) connected to |
the C220 Tube Preamplifier. |
3. The Main AC Power going to the C220 and any other |
McIntosh Component(s) should not be applied until all |
XLR Connectors
Below is the Pin configuration for the XLR Balanced Input
and Output Connectors on the C220. Refer to the diagrams | |||
for connections: |
|
|
|
PIN 1: Shield/Ground |
|
|
|
PIN 2: + Output |
|
|
|
PIN 3: - Output |
|
|
|
PIN 2 | PIN 1 | PIN 1 | PIN 2 |
PIN 3 |
|
| PIN 3 |
the system components are connected together. Failure |
to do so could result in malfunctioning of some or all |
of the system’s normal operations. When the C220 and |
other McIntosh Components are in their Standby Power |
Off Mode, the Microprocessor’s Circuitry inside each |
component is active and communication is occurring |
between them. |
4. Up to two Sensors can be wired in parallel for Remote |
Power Control and Trigger Connectors The C220 Power Control and Trigger Output Power On/Off Signals when connected
to McIntosh and other Components. A 1/8 inch stereo mini phone plug is used for connection to the Power Control and Trigger Outputs on the C220.
Jacks send
N/C
Ground
Control of the C220 from other rooms. |
5. Balanced and Unbalanced Inputs and Outputs can be |
mixed. For example, you may connect signal sources to |
Unbalanced Inputs and send signals from the Balanced |
Outputs. You can also use Balanced and Unbalanced |
Outputs simultaneously, connected to different Power |
Amplifiers. |
6. A McIntosh Power Controller may be added to the C220 |
to provide AC Power Switching to components that do |
not have Power Control Connections. See your McIn- |
tosh Dealer for additional information. |
Note: The Data, Power Control and |
|
|
|
|
|
|
|
|
Trigger |
|
|
|
|
| |||
Trigger Connecting Cable is |
|
|
|
|
| |||
Control |
|
|
|
|
| |||
|
|
|
|
| ||||
|
|
|
|
| ||||
available from the McIntosh | N/C |
|
|
|
|
| ||
|
|
|
|
| ||||
|
|
|
|
| ||||
|
|
|
|
| ||||
|
|
|
|
| ||||
Parts Department: |
|
|
|
|
| |||
|
|
|
|
|
|
|
| |
Data, Power Control and Trig- | Ground |
|
|
|
|
| ||
ger Cable Part No. |
|
|
|
|
|
|
|
|
Six foot, shielded 2 conductor, with 1/8 inch stereo mini phone plugs on each end.
Data Port Connectors
The C220 Data Out Ports send Remote Control Signals to McIntosh Source Components. A 1/8 inch stereo mini phone plug is used for connection.
N/C
Data
Ground
4