Customising 562 using Config | 18 |
|
|
Customising using Config
For an overview of Config, see page 13
In Config you can review and change settings to do with communications, control and the hardware options you have. In Config you also make choices about the number and types of sources, what the display shows when you select them etc. The 562 is initially programmed to Type 1 and all Types set up the source configuration as shown in the previous Tables.
For more details of comms mode see page ??.
How to use Config
1.Switch off any power amplifiers that are connected to 562.
2.Switch off the 562 using the power switch on the back.
3.While pressing the Source key on the 562 front panel, switch the power on again. The display will read:
Conf
4.Release the Source key, the display will show:
500
Selecting comms mode
In Config mode:
1. Press Copy until you see a display like:
500
1.Use the and , Volume keys to choose 500 or 200 For guidance on this question see Page ??.
Selecting the controller mode
In Config mode:
1.Press Copy until you see a display like:
Auto
2.Use the and , Volume keys to choose between:
∙Auto, meaning configuring can be automatic
∙Cont, meaning the 562 will be the system controller
∙NCon, meaning the 562 will not be the controller
For guidance on this question see Page ??.
Note This setting has no meaning in 200 comms mode
Setting the system address for 562
In Config mode:
1.Press Copy until you see a display like:
SA=1
This means the system address is 1. The Meridian 500 comms system allows for up to eight systems operating on the same network. Unless you are setting up a Multiroom system, or are advised to do so by Meridian support personnel, we suggest you leave this on address 1.
Note This setting has no meaning in 200 comms mode
Setting the product address for 562
In Config mode:
1.Press Copy until you see a display like:
PA=1
562 User Guide