Technical information | 29 |
|
|
on the D6000 handset. The first number displayed will either be 1.x or 2.x.)
∙systems using DSP5000 with software versions less than 2.0. (To see the version of your DSP5000s put them into standby and then press Display on the DSP5000 handset. The first number displayed will either be 1.x or 2.x.)
D5000s and D6000s may be upgraded to an EPROM version 2.0 or greater that allows 500 mode operation, and considerable user benefits.
D600 does not have a software upgrade, the options are to use 200 mode or to upgrade the D600 to DSP5000B by changing the electronics panel.
If you have DSP5000s or D6000s with software version 2.0 or greater, then move to the following section, ‘500 mode digital speakers’ and follow the instructions for D5000.
200 Mode digital speakers
Note If you operate the speakers in 200 mode, then all Meridian 500 Series products must be set to 200 mode. See the instructions that came with each product. In general it will be necessary to select a Type in the same way as 562 and if in doubt choose Type 2.
Do the following:
1.Connect the phono plug on the end of the
2.Connect one of the two DIN plugs on one end of the
3.Setup the speakers according to the manual, selecting a Type that expects a preamplifier (like 201).
∙D600 start with Type ??.
∙D6000 version 1.x start with Type ??.
∙DSP5000 version 1.x start with Type ??.
∙D6000 version 2.x start with Type 2.
∙DSP5000 version 2.x start with Type 2.
4.Set the 562 to Type 2 (see the instructions on page ??.
5.Set other 500 components to Type 2.
Note There are usually two DIN plugs on an
In 200 mode the following differences apply to 562.
∙You can control the complete system with the 609, DSP5000 or D6000 Remote supplied with the speakers.
∙Volume control and mute are handled by the speakers.
∙Sources can be selected remotely via the loudspeakers or from the front panel of 562.
∙Muting can be controlled from the front panel of 562.
∙Only 8 sources are available in the 200 comms system.
Custom Config
If you choose to do your own configuring for 562, then ensure that the following choices are made:
∙200 mode
∙NCon
∙SA=1
∙PA=1
∙CD?Y