Metrologic Instruments MLPN 2159 manual Appendix B, Pin Assignments

Models: MLPN 2159

1 28
Download 28 pages 5.19 Kb
Page 20
Image 20

Appendix B

Pin Assignments

Version “1” Pin Assignments for RS-232, OCIA, and Bidirectional RS-232

Each TECH 7 scanner has a 19-pin male Mil spec connector that is located on the side of the unit. To connect the scanner to the host device, use a communication cable with a female Mil spec connector. The communication cable may include a power supply or it may be designed to draw power directly from the host device. This item can be ordered when the scanner is purchased.

The Version “1” scanner is designed to be used for RS-232, OCIA, and RS-232 with limited receiving capabilities.

The following is a list of pin assignments. The pin numbers are impressed on the male Mil spec connector. For easier reference, refer to Figure 9 for pin locations.

Pin

Function

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

R Data

 

 

 

 

 

B

RTS Output

 

 

 

 

 

C

Signal Ground

 

 

 

 

 

D

CTS Input

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E

R Data Return

 

 

 

 

 

F

RS-232 Output

 

 

 

 

 

G

Clock in

 

 

 

 

 

H

Clock in Return

 

 

 

 

 

J

Clock Out

 

 

 

 

 

 

 

 

 

K

Shield Ground

Figure 9

L

DTR Input

 

 

 

 

M

Clock Out Return

 

 

 

 

NPower to Scanner & 24 VDC

P Earth Ground

R Power Ground

S RS-232 Input

17

Page 20
Image 20
Metrologic Instruments MLPN 2159 manual Appendix B, Pin Assignments