29
Operational
Depth of Field: 0" - 4"; 0"- 8" (programmable)
0 - 101.6mm; 0 - 203.2mm
Scan Speed: 1000 scan lines per second
Scan Pattern: 5 fields of 4 parallel lines
Scan Lines: 20
Min Bar Width: 5.2 mil
Indicators (LED): red = laser on, ready to scan
green = good read, decoding
Beeper Operation: 3 tones or no beep
Maintenance: Clean output window periodically
Decode Capability: Autodiscriminates all standard bar codes;
for other symbologies call Metrologic
System Interfaces: Keyboard Wedge, RS-232, OCIA, Light Pen, IBM
46xx
Print Contrast: 35% minimum reflectance difference
Roll, Pitch, Yaw: 360E, 60E, 60E
Environmental
Storage Temperature: -40EC to 60EC (-40EF to 140EF)
Operating Temperature: 0EC to 35EC (32EF to 95EF)
Humidity: 5% to 95% relative humidity, non-condensing
Light Levels: Up to 300 LUX
Ventilation: None required
Shock: 1m. (40") drop
Contaminants: Sealed to resist airborne particulate contaminants
This Metrologic product may be covered by one or more of the following U.S.
patents:
5, 073,702, 5,115,333, 5, 216,232, 5,484,992, 5,525,789, 5,557,093,
5,591,953, 5,616,908.