INSTALLATION OF THE 6000 SERIES UNIVERSAL CHARGING STAND

MLPN: 45558 - 115V, 45559 - 230V and 45560 - 240V (UK)

Transformer

Green LED

(Charge Status)

Red LED

(Power)

Figure 6: Universal Charging Stand

PERMANENT COUNTER TOP INSTALLATION

1.Separate weighted base from rotating base by removing the (4) four screws.

2.Use the rotating base as a drill template.

3.Use the (4) four wood screws provided to mount the base to the counter top securely.

4.Snap the cup assembly to the base.

Note: For non-permanent installation, snap the cup assembly onto the weighted base

CHARGE STATE

CHARGE LED STATUS

 

 

Battery Absent

LED off

 

 

Charge Pending

LED on for 0.125sec,

off for 1.375sec

 

 

 

Fast-Charge

LED on

 

 

Charge Complete and Top-Off

LED on for 0.125 sec,

off for 0.125sec

 

 

 

 

 

22