APPENDIX C

MX003 Series Scanner Interface Pin Assignments

The interfaces are equipped with a shielded, 10-pin modular jack manufactured by Steward Stamping. The mating connector is a Steward Stamping shielded plug #937-SP-361010. Caution should be used when working with cables for this port because there is typically power present for scanner interface operation.

Models MX003, MX0033 and MX0034:

Pin

Function

1

Power (d/c)/Shield Ground

2

RS-232 Transmit Output

3

RS-232 Receiver Input

4

RTS Output

5

CTS Input

6

DTR Input

7

LP/DATA

8

NC

9

+5Vdc Power to Scanner Interface

10

NC

Models MX003-17, MX0033-17 and MX0034-17:

Pin

Function

1

Power (d/c)/Shield Ground

2

RS-232 Transmit Output

3

RS-232 Receiver Input

4

Keyboard Data

5

Keyboard Clock

6

PC Clock

7

PC Data

8

NC

9

PC +5V/ External +5V

10

NC