Appendix A: Post Messages
| Message | Possible Cause | Solution |
|
|
|
|
|
|
| MONITOR TYPE | Monitor type not | Run Setup and enter |
|
| DOES NOT MATCH | correctly identified in | correct monitor type. |
|
| CMOS | Setup. |
|
|
|
|
|
|
|
| OPERATING | Operating system | Check Setup to see if |
|
| SYSTEM NOT | cannot be located on | Drive A: and C: are |
|
| FOUND | Drive C: or Drive A: | properly configured, or |
|
|
|
| put a bootable disk in |
|
|
|
| Drive A: |
|
|
|
|
|
|
| PARITY CHECK 1 | Parity error found in the | Check Setup. Board |
|
| nnnn | system bus. | repair may be required. |
|
|
|
|
|
|
| PARITY CHECK 2 | Parity error found in the | Check Setup. Board |
|
| nnnn | I/O bus. | repair may be required. |
|
|
|
|
|
|
| PREVIOUS BOOT | Previous POST did not | Run Setup, load default |
|
| INCOMPLETE - | complete successfully. | BIOS settings, make any |
|
| DEFAULT |
| necessary adjustments, |
|
| CONFIGURATION |
| and save the changes |
|
| USED |
|
|
|
|
|
|
|
|
| REAL TIME CLOCK | May require battery |
| |
| ERROR | BIOS test. | replacement or board |
|
|
|
| repair. |
|
|
|
|
|
|
| SHADOW RAM | Shadow RAM failed. | May require repair of |
|
| FAILED AT OFFSET |
| system board. |
|
|
|
|
|
|
| SYSTEM BATTERY | System battery died. | Replace the system |
|
| IS DEAD |
| battery and run Setup to |
|
|
|
| reconfigure the system. |
|
|
|
|
|
|
| SYSTEM CACHE | External (L2) cache | System will still run, but |
|
| ERROR - CACHE | failed BIOS test. | slower. Replace cache |
|
| DISABLED |
| at convenience. |
|
|
|
|
|
|
| SYSTEM CMOS | System CMOS has been | Run Setup and |
|
| CHECKSUM BAD - | corrupted or modified | reconfigure the system. |
|
| RUN SETUP | incorrectly. |
|
|
|
|
|
|
|
| SYSTEM RAM | System RAM failed. | Replace defective RAM. |
|
| FAILED AT |
|
|
|
| OFFSET: nnnn |
|
|
|
|
|
|
|
|
| SYSTEM TIMER | Timer test failed. | Requires repair of system |
|
| ERROR |
| board. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
M54E2 System Board Manual |