SECTION 2
INSTALLATION
UTILITY
FOR
WARNING
DO NOT USE CONDUIT OR GAS LINE FOR GROUND CONNECTION.
CAUTION
IT IS RECOMMENDED THAT THE OVEN BE PLACED UNDER A VENTILATION HOOD FOR ADEQUATE AIR SUPPLY AND VENTILATION.
ELECTRIC SUPPLY TO BE
PROVIDED BY CUSTOMER
CIRCUIT BREAKER
Separate circuit breaker with lockout/tagout electrical shutoff for each oven. Wire each oven separately.
60 Amp circuit breaker for
ELECTRICAL SPECIFICATIONS
Blower/ | 208V | 240V | 380V | 480V | 280V | 230V | 240V | |
Element | ||||||||
|
|
|
|
|
|
| ||
Phase | 3 | 3 | 3 | 3 | 1 | 1 | 1 | |
|
|
|
|
|
|
|
| |
Circuit | 208/240 | 208/240 | 208/240 | 208/240 | 208/240 | 208/240 | 208/240 | |
|
|
|
|
|
|
|
| |
kW | 12 | 12 | 12 | 12 | 10 | 9.2 | 10 | |
|
|
|
|
|
|
|
| |
Frequency | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 | |
|
|
|
|
|
|
|
| |
Poles | 3 | 4 | 4 | 4 | 2 | 2 | 2 | |
|
|
|
|
|
|
|
| |
Wires | 4 | 5 | 5 | 5 | 3 | 3 | 2 | |
|
|
|
|
|
|
|
| |
L1 | 35.3 | 30.8 | 20.2 | 16.4 | 48.1 | 40.0 | 41.7 | |
|
|
|
|
|
|
|
| |
L2 | 35.3 | 30.8 | 18.2 | 14.4 | 48.1 | 40.0 | 41.7 | |
|
|
|
|
|
|
|
| |
L3 | 33.3 | 28.8 | 18.2 | 14.4 | - | - | - | |
|
|
|
|
|
|
|
| |
N | - | - | 2.0 | 2.0 | - | - | - | |
|
|
|
|
|
|
|
|
Figure 2-9. Typical PS528-Series Oven(s)
Installation
CAUTION
UNIT MUST HAVE AIR VENT PLATES
INSTALLED OR WARRANTY WILL BE VOID.
II. VENTILATION GUIDELINES
A mechanically driven ventilation system is recommended for the PS528 Series Middleby Marshall conveyorized electric ovens.
Local codes and conditions vary greatly from one area to another and must be complied with. Following are the sug- gested requirements for good ventilation. Please remember these are recommendations or guidelines, you may have a special condition or problem that will require the services of a ventilation engineer or specialist. Proper ventilation is the oven owner’s responsibility. Improper ventilation can inhibit oven performance.
Please Note: There are now two “stand off” ‘C’ Channels
that must be installed in the field (See Section 6: PARTS LIST, page
SUPPLY WIRE
Supply wire size must be in accordance with the National Electrical Code (current edition) and must be in compli- ance with local codes.
SUGGESTED
If space permits, service should be located near the control console end of the oven(s) to allow convenient access to safety switches.
12